BATTERY GUARD
Intelligent Battery Guard
Model No.
BGB 250
Please read this manual before operating your Battery Guard
Owners Manual
Page 1: ...BATTERY GUARD Intelligent Battery Guard Model No BGB 250 Please read this manual before operating your Battery Guard Owners Manual ...
Page 2: ...ormally and the device begins to check the voltage once more If the voltage remains under the set level the relay will switch off after 70 seconds The LED will also switch off After detecting undervoltage the relay will only switch on again once the voltage has risen above the reset value for a period of 5 seconds At the same time the LED lights up again Switching on manually If the BGB 250 has sw...
Page 3: ...e diameters Flange connectors T1 T2 minimum Ø 50 mm2 Faston connectors minimum Ø 1 5 mm2 Electronic information Autodetect 12 V or 24 V system 12 V mode 24 V mode 8 V t m 19 V 19 V t m 35 V Current consuption Active Passive 3 mA 2 mA Inrush current 100ms 12 V mode 24 V mode 2 6 A 5 0 A Switching current Continuous Peak 250 A 1500 A Connection diagram ...