background image

Owner's

Manual

Please read this 

manual before  

installing your 

fuse block

Class T Fuse Blocks
CFB1-200

200 Amp

CFB2-400

400 Amp

4

1

11013-CFB1-CFB2-1021

MAN-10006

2 YEAR LIMITED WARRANTY

The CFB1-200 and CFB2-400 fuse blocks manufactured by Samlex America Inc. (the “War-
rantor“) are warranted to be free from defects in workmanship and materials under 
normal use and service. The warranty period is 2 years for the United States and Canada, 
and is in effect from the date of purchase by the user (the “Purchaser“). 

Warranty outside of the United States and Canada is limited to 6 months. For a warranty 
claim, the Purchaser should contact the place of purchase to obtain a Return Authoriza-
tion Number. 

The defective part or unit should be returned at the Purchaser’s expense to the authorized 
location. A written statement describing the nature of the defect, the date of purchase, 
the place of purchase, and the Purchaser’s name, address and telephone number should 
also be included.

If upon the Warrantor’s examination, the defect proves to be the result of defective mate- 
rial or workmanship, the equipment will be repaired or replaced at the Warrantor’s option 
without charge, and returned to the Purchaser at the Warrantor’s expense. (Contiguous 
US and Canada only)

No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is 
unable to remedy the defect after having a reasonable number of opportunities to do so. 
Warranty service shall be performed only by the Warrantor. Any attempt to remedy the 
defect by anyone other than the Warrantor shall render this warranty void. There shall  
be no warranty for defects or damages caused by faulty installation or hook-up, abuse or 
misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or 
water immersion.

No other express warranty is hereby given and there are no warranties which extend 
beyond those described herein. This warranty is expressly in lieu of any other expressed 
or implied warranties, including any implied warranty of merchantability, fitness for the 
ordinary purposes for which such goods are used, or fitness for a particular purpose, or 
any other obligations on the part of the Warrantor or its employees and representatives. 

There shall be no responsibility or liability whatsoever on the part of the Warrantor or 
its employees and representatives for injury to any persons, or damage to person or 
persons, or damage to property, or loss of income or profit, or any other consequential or 
resulting damage which may be claimed to have been incurred through the use or sale of 
the equipment, including any possible failure of malfunction of the equipment, or part 
thereof. The Warrantor assumes no liability for incidental or consequential damages of 
any kind. 

Samlex America Inc. (the “Warrantor”)
www.samlexamerica.com

103 - 4268 Lozells Ave.
Burnaby, BC 
Canada  V5A 0C6

T: 604 525 3836
F: 604 525 5221
TF: 1 800 561 5885

[email protected]
www.samlexsolar.com

INTRODUCTION 

The CFB1-200 and the CFB2-400 are fuse blocks with a 200A and 400A Class T fuse.  The 
assembly is designed for surface mounting and incorporates a screw down terminal for cable 
termination.
These fuse blocks should be installed as close to the battery on the positive side (in a positive 
system) to limit injury and damage caused by a short circuit of the positive side of the battery.

CONSTRUCTION 

The Class T Fuse Block (Fig. 1) contains the following components:
  •  Fuse Holder: A fiberglass insulated base with a removable polycarbonate cover
  •  Class T Type Fuse: 200A or 400A Fuse (JLLN or equivalent); 20 k Interrupting Capacity (DC)
 

CFB1-200 comes with a 200A Fuse.

 

CFB2-400 comes with a 400A Fuse.

  •   A CFB1 will not support a 400A Fuse and the CFB2 will not support a 200A Fuse

Fig. 1.CFB1 and CFB2  Class “T” Fuse Assembly

Fig 2 Class “T” Fuse and Fuse Block

Reviews: