SAMITECH Heat Wrap User Manual Download Page 1

Samitech Heat Wrap User Manual V1.0.220610 

 

 

 

user manual 

Heat Wrap 

 

Samitech Heat Wrap is a physical heat solution against 
xylophages. 

Modular set consisting of 6 heating panels adaptable to 
any surface. 

Heat Wrap uses Samitech’s exclusive infrared heating 

technology. 

Summary of Contents for Heat Wrap

Page 1: ...V1 0 220610 user manual Heat Wrap Samitech Heat Wrap is a physical heat solution against xylophages Modular set consisting of 6 heating panels adaptable to any surface Heat Wrap uses Samitech s exclus...

Page 2: ...ctions 9 Status indicators 10 Necessary checks before each treatment 11 References for treatment durations 12 Precautions during treatments 12 User interface 14 Main menu 14 New treatment 15 Advisory...

Page 3: ...kind of wood SAMITECH has revolutionised the pest control business with their infrared technology that penetrate treated objects killing any insect by dehydration Heat Wrap is effective against any wo...

Page 4: ...se you avoid the need to heat up all air surrounding treated objects Samitech s heating panels radiate infrared waves that penetrate deeply into treated objects attacking the protein molecules of xylo...

Page 5: ...any wood surface Heating panels are controlled and monitored with an electronic Control Unit A free downloadable app compatible with both iOS and Android will act as the user s interface to setup and...

Page 6: ...p on both sides These straps allow to wrap objects like pillars or beams and are also suitable to form mosaics with other panels to cover bigger surfaces in floor wall or ceiling treatments Eyelets Ea...

Page 7: ...ntinuity in the total treatment surface you can avoid this gap by overlapping the panels up to 6cm Remember you should never overlap the heating panels beyond this safety perimeter The picture shows t...

Page 8: ...eral panels by means of the Velcro straps If surface to be treated is larger than surface covered with all 6 panels you can do the treatment in stages but you should move the panels after each treatme...

Page 9: ...n the app You can plug each panel to any socket in the Control Unit Optionally connect one or both temperature probes to indicated sockets in the Control Unit Connect the power cable to the Control Un...

Page 10: ...luetooth status This amber indicator shows that there is a problem in any heating panel Number of flashes indicate panel number with an issue In case of a problem is any panel switch off the Control U...

Page 11: ...otos jewels etc Documents money Magnetic optical solid and mechanical media and storage devices hard drives SSD USB pen drives video tapes cassettes etc Flammable or combustible materials solvents oil...

Page 12: ...ical treatment times depending on type of wood and taking maximum temperature of 100 C 212 F as a reference Beams and columns Low density wood High density wood Thickness Low humidity 2 6 High humidit...

Page 13: ...bort treatment press the red button STOP Treatment will be aborted immediately Once treatment is finished wait at least 10 minutes before removing panels in order for the heat to cool down Generated h...

Page 14: ...monitor its progress User may also take pictures of treated objects before and after treatment as proof of their condition Once treatment is finished the App can generate a report including all treat...

Page 15: ...runs a self test to check that everything is running as it should 2 Heating During this phase heating panels reach defined working temperature 3 Treatment During this phase heating panels maintain de...

Page 16: ...ment Treatment report Once treatment is completed successfully user may choose to generate a detailed PDF report This report will include all relevant treatment parameters such as temperature duration...

Page 17: ...on any treatment system will show PDF generated report for that treatment which can then be shared Devices This screen allows to choose which Control Unit is to be controlled in case more than one is...

Page 18: ...in local currency per kWh Pest Control Company s logo and contact details to be used as letterhead in the reports There is an additional setting option that allows to eliminate the Advisory and Safet...

Page 19: ...y of objects equipment or the place where you plan to do the treatment Make sure you have adequate fire detection and extinguishing equipment before you start any treatment Warnings about electrical h...

Page 20: ...ls to cool before you remove treated objects Never let heating panels touch your skin immediately after treatments After your last treatment carefully clean with a dry cloth those parts of the equipme...