13
DRT7145
C - 2022/11
Member of Exel group
3.2. Electrical characteristics
The
Inobox
control module is intended to be installed in
category II (according to EN 61010-1)
.
(*): The maximum power value is given all active functions simutaneously. (HV and Air).
3.3. Air compressed quality
Characteristics of compressed air supply according to the standard NF ISO 8573-1 :
*: Values are given for a temperature of 20 °C (68 °F) at an atmospheric pressure of 1 013 mbar
Non-compliance with these characteristics may result in incorrect operation of the“Inobox”
control module.
The control module is equipped with an internal air regulator which allows air flows independent of the air supply
system, within the operating range 7 bar +/-1bar.
Supply voltage
100 VAC at 240 VAC / 50 Hz - 60 Hz
Maximum Input Power (*)
105 W at 230 VAC
Maximum current
0.56 A at 230 VAC / 0.95 A at 115 VAC
Protection circuit
Fuse 1.25A 5x20 HPC
Max. output voltage
42 V rms
Max. output current
400 mA rms
Maximum frequency (to projector)
22.5 kHz +/-20% (min. 18 kHz / max. 30 kHz)
Pressure supply
7 bars +/-1bar
Output voltage vibrator / smoke suction
100 VAC at 240 VAC +/- 2% /50 Hz – 60 Hz
Output power vibrator / smoke suction
45 W
Max current of the vibrator/smoke suction output
0.48 at 230 VAC / 0.96 A at 115 VAC
Maximum dew point at 6 bar (87 psi)
Class 4 i.e + 3°C (37°F)
Maximum particle-size of solid pollutants
Class 3 i.e 5
μ
m
Maximum oil concentration
Class 1 i.e 0.01 mg/m
0
3
*
Maximum concentration of solid pollutants
Class 3 i.e 5 mg/m
0
3
*