![SAMES KREMLIN Inorecip V User Manual Download Page 6](http://html1.mh-extra.com/html/sames-kremlin/inorecip-v/inorecip-v_user-manual_3699181006.webp)
Index revision : A
6
7140
1.2. Simplified analysis of potential ignition sources according to EN 80079-36
1.3.
Precautions for Use
This document contains information that all operators should be aware of and understand
before using the
Inorecip V and Inomotion.
This information highlights situations that could result
in serious damage and indicates the precautions that should be taken to avoid them.
WARNING : Before any use of the equipment, check that all operators:
• have previously be trained by the compagny
SAMES KREMLIN
, or by their distributors
registered by them for this purpose.
• have read and understood the user manual and all rules for installation and operation, as
laid out below.
It is the responsibility of the operators’ workshop manager to ensure these two points and it is
also his responsibility to make sure that all operators have read and understood the user
manuals for any peripheral electrical equipment present in the powdering area.
1.4.
Warnings
DANGER:
It is imperative that anyone wearing a pacemaker does not use the equipment and does not
enter the projection area.
High voltage can cause the pacemaker to malfunction.
WARNING : Safety may be jeopardized if this equipment is not operated, disassembled and
reassembled in compliance with the instructions given in this manual and in any
European Standard or national safety regulations in force.
Risk of ignition
Measures applied to prevent the
source of ignition from becoming
effective
Potential
source of igni-
tion
Description / Main cause
(What are the conditions causing
the risk of ignition)
Description of the measure applied
Hot surface
Friction of the drive belt on the pul-
leys and of the rollers on the rails
Plastic belt: does not transmit heat
Moving speed < 36m/min
Sparks of
mechanical
origin
Sparks caused by the fall of the car-
riages (belt breaking) or by a
change in the stroke of the car-
riages
Carriages equipped with high and low
elastic stops
Static electri-
city
Electrostatic discharge between
metal parts and earth (e.g. rollers /
rails, pulley / axis / belt)
All metal parts must be earthed.
Electrostatic discharge at the belt
Antistatic belt