26
4.4.1
Description of the ATEX marking
Each device is marked with the name of the manufacturer, the
reference of the device and important information for the use of the
device (air pressure, electrical power, etc.).
This equipment has been designed in accordance with the ATEX
2014/34/EU directive and is intended for use in Zone 1.
Description
Acronym SAMES KREMLIN
Manufacturer's brand name
FPro
Gun model
EC
EC
: European Conformity
II 2 G
:
Use in explosive areas
II
: group II
2
: category 2
Surface equipment intended for an environment in which
explosive atmospheres due to gases, vapours, mists are likely to
occur occasionally during normal operation.
G
: Gas
Ex h IIB T6
Ex
Marking of conformity to European standards
h
: Type of protection for non-electrical appliance
IIB
: Reference gas for equipment qualification
T6
: Temperature class
- Maximum surface temperature: 85°C*.
Gb
Gb
: Equipment protection level (zone 1 gas)
X
Special conditions apply for safe use.
Refer to the requirements in the instruction manuals
accompanying this product.
20XX
Number given by SAMES KREMLIN.
The first two digits indicate the year of manufacture.
P air : 6 bar / 87 psi
Max. air supply pressure of the gun
P prod : 6 bar / 87 psi
Max. fluid pressure at gun inlet
PATENT PENDING
Patent pending on Vortex technology
GSP KIT Specificity
P air : 1 bar / 14 psi
Maximum allowable pressure in the GSP cup: 1 bar / 14 psi
Summary of Contents for FPro G
Page 27: ...27 4 4 2 Visuals of the marking elements FPro G CONV FPro G LP FPro G GSP...
Page 55: ...55 Step 13 Raising the trigger Step 14 Feed in air and product...
Page 56: ...56 10 4 3 Replace air valve Step 1 Loosen the nut...
Page 60: ...60 Step 9 Back up The greased needle The needle spring The needle stop Tighten the nut...
Page 65: ...65 Step 1 To remove the hose apply pressure from top to bottom on the arrowed element...
Page 74: ...74 Step 3 Install the new anti drip membrane Step 4 Screw on the gravity cup by hand...