582108110-EN-indG-Pompe Azur-52C225.docxx
25
4
Environment
The equipment must be installed on a horizontal, stable and flat ground
(eg concrete slab).
Non-moving equipment must be secured by suitable fixing devices
(spit, screws, bolts, etc.) to ensure its stability during use.
To avoid risks due to static electricity, the equipment and its
components must be grounded.
For pumping equipment
(pumps, elevators, chassis, etc.),
a 2.5 mm section wire is attached to the equipment. Use
this wire to connect the equipment to the general
“earth”. In severe environments (mechanical protection
of the ground wire, vibrations, moving equipment, etc.)
where damage to the grounding function is likely, the
user will have to replace the wire of 2, 5 mm supplied, by
a device more adapted to its environment (wire of
greater section, braid of mass, fixing by lug with eyelet
…).
Have the earth continuity checked by a qualified
electrician. If earth continuity is not assured, check
terminal, wire and grounding point. Never operate the
equipment without solving this problem.
The gun must be "grounded" through the fluid hose.
When spraying from a gun, the fluid hose must be
conductive.
The materials to be painted must also be “grounded” by
means of clamps with cables or, if they are suspended,
by means of hooks which must remain permanently
clean.
Note: all objects in the work area must also be grounded.
Summary of Contents for 64350225130000
Page 41: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 41 8 Equipment plans Pump 52C225...
Page 42: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 42 Wall mounted pump...
Page 43: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 43 Pump 52C225 Cart...
Page 44: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 44 Pump 52C225 Cart Hopper...
Page 45: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 45 Fluid section C225...
Page 46: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 46 Motor 7000 Stroke 120...
Page 47: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 47 Air supply...
Page 48: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 48 Filter...
Page 49: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 49 Pump priming kit...
Page 50: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 50 Hopper...
Page 167: ...Pneumatic Wiring 582108110 EN indG Pompe Azur 52C225 docx 167 Indirect air control...
Page 214: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 214...
Page 215: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 215...