Safety instructions
582108110-EN-indG-Pompe Azur-52C225.docx
18
Injection hazards
“HIGH PRESSURE” technology requires the utmost care.
Operation can cause dangerous leaks. There is a risk of product
injection into exposed parts of the body, which can lead to serious
injury and the risk of amputation:
An injection of product into the skin or other parts of the
body (eyes, fingers …) must be treated urgently by
appropriate medical care.
Do not look at the gun nozzle when it is under pressure.
Never direct the jet to another person.
Never attempt to stop the jet with the body (hands,
fingers …) or with rags or similar.
Fire hazards, explosion,
electric arc, static
electricity
Improper grounding, insufficient ventilation, open flames or sparks can
cause an explosion or fire which could result in serious injury.
To avoid these risks, especially when using pumps, it is imperative:
To connect the equipment, the parts to be treated, the
cans of products and cleaners to the ground,
To ensure good ventilation,
Keep the work area clean and free of rags, papers,
solvents,
Do not operate electrical switches in the presence of
vapors or during removal,
Immediately stop the application in the presence of arcs,
Store all liquids outside the work areas.
Use products whose flash point is as high as possible to
avoid any risk of formation of flammable gases and
vapors (consult the product safety data sheets).
To equip the drums with a lid to reduce the diffusion of
gases and vapors in the cabin.
It is forbidden to pump explosive materials
Summary of Contents for 64350225130000
Page 41: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 41 8 Equipment plans Pump 52C225...
Page 42: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 42 Wall mounted pump...
Page 43: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 43 Pump 52C225 Cart...
Page 44: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 44 Pump 52C225 Cart Hopper...
Page 45: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 45 Fluid section C225...
Page 46: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 46 Motor 7000 Stroke 120...
Page 47: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 47 Air supply...
Page 48: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 48 Filter...
Page 49: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docxx 49 Pump priming kit...
Page 50: ...Equipment plans 582108110 EN indG Pompe Azur 52C225 docx 50 Hopper...
Page 167: ...Pneumatic Wiring 582108110 EN indG Pompe Azur 52C225 docx 167 Indirect air control...
Page 214: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 214...
Page 215: ...Spare parts 582108110 EN indG Pompe Azur 52C225 docx 215...