Rough
Cam
®
IPQ1615
User Manual
Page 1: ...RoughCam IPQ1615 User Manual ...
Page 2: ...ons 9 4 Installation 10 5 Electrical connection 12 5 1 Potential equalization 12 5 2 Connection work at the device terminal box and fuses 13 5 2 1 Fusing 18 5 2 2 Plug assignments RJ45 19 5 2 3 Tests prior to switching on voltage 20 6 Working inside the camera housing 20 6 1 Preparation for work 20 6 2 Opening the housing 21 6 3 Removing inserting a SD memory card 23 6 4 Hardware Reset 24 6 5 Clos...
Page 3: ... L ASKD02 T 14 Table 5 4 Wire assignment of terminal box integrated heater 15 Table 5 5 Wire assignment of terminal box model LL ASKDP03 T 15 Figure 5 5 Sample circuit of terminal box without heater 16 Figure 5 6 Sample circuit of terminal box heater integrated 17 Figure 5 7 Photo of the wired terminal box 17 Table 5 6 Recommendation for fusing 18 Figure 5 8 Plug assignment RJ45 19 Figure 6 1 Remo...
Page 4: ...r applications It is extreme ly robust and therefore perfect for even the roughest industrial conditions The stainless steel housing allows additional alloys a powder coating or coats of varnishes as well as various mechanical accessories in order to extend the resistance towards extreme envi ronmental conditions salt water acid solar radiation high mechanical strains etc Due to the usage of high ...
Page 5: ... with large diameter ØVA2 113mm VA2 3 K3 BOR2 T11 VA2 3 housing with maximum body length L R 310mm VA2 3 K3 BOR2 K3 cable gland flange VA2 3 K3 BOR2 Borosilicate sight glass DIN7080 standard for video cameras within visible spectral range λ 350 2000 nm and photografical infrared range NIR not suitable for thermographic applications MIR FIR 4 N X Normal ambient temperature range no heater installed...
Page 6: ... 54 V DC Maximum power consumption 12 95 W Typical power consumption 8 2 W 2 3 Connection cable Description Data transfer and power supply of the camera module compliant with DIN EN 60079 14 Jacket colour Green GN similar to RAL3001 2 3 1 Connection cable for models without heater SKD01 T ASKD02 T Systemcable SKD01 T Outside diameter 9 1 0 2 mm Bending radius 10 x Da when installed 5 x Da after re...
Page 7: ...nts en 60 Assembling 26mounting ASKD02 T_Datasheet pdf Figure 2 2 Sectional view of ASKD02 T 2 3 2 Connection cable for models with heater SKDP03 T ASKDP03 T Systemcable SKDP03 T Outside diameter 12 40 0 3 mm Bending radius 8 x Da when installed and 4 x Da after relocation Data line 4 x 2 x AWG23 1 CAT 6 Performance elements 3G1 5 BK BU GN YE Properties PUR halogen free flame retardant UV resistan...
Page 8: ...in documents en 60 Assembling 26mounting ASKDP03 T_Datasheet pdf Figure 2 4 Sectional view of ASKDP03 T 2 4 Video technical characteristics We use the AXIS Q 1615 MkIII Network Camera in a pressure resistant enclosure For details please refer to the Product Documentation video technical data of AXIS https www axis com products axis q1615 mkiii 2 5 Other technical data Protection class IP 68 IEC EN...
Page 9: ...he na tionally applied regulations and exclusively by the manufacturer Attention Prior to installation take external sources of heat or cold into account The temperature ranges prescribed for storage transport and operat ing must be adhered to Camera Terminal box Permissible ambient temperature 10 C 60 C for PoE power supply 60 C 60 C In the event of additional 24 V DC power supply 60 C 55 C Prote...
Page 10: ...m object distance to the focus Use appropriate tools and aids When working ensure a safe stand Make sure that any static charge is avoided Attention Please observe the national security installation and accident preven tion regulations and the safety instructions in this User Manual The RoughCam IPQ1615 consists of a camera housing and optionally models with a terminal box T a terminal box Both un...
Page 11: ...inless steel 1 4404 Load bearing 45 kg Dimensions 445 x 140 x 185 mm Weather protec tion roof WPR WEATHER PROTECTION ROOF WPR VA2 3 Weathershield for cameras of the T10 VA2 3 Series Pole adapter PMB WALL MOUNT BRACKET PMB VA2 3 Pole adapter for VA wall mount Material stainless steel 1 4404 Suitable for pole diameters between 50 and 100 mm Load bearing capacity 50 kg Dimensions 120 x 180 x 130 pole...
Page 12: ...vidually specified by the client The user is NOT authorised to do electrical connection procedures inside the pressure resistant enclosure 5 1 Potential equalization Figure 5 1 RoughCam IPQ1615 Potential equalization Potential equalization grounding of the camera housing is absolutely necessary in order to avoid static charges and thus the formation of sparks For this purpose a screw termi nal is ...
Page 13: ... 3af 802 3at type 1 class 3 Reference voltage 48 V DC 44 54 V DC Maximum power consumption 12 95 W Typical power consumption 8 2 W The figures 5 2 and 5 3 illustrate the potential cable terminations of the RoughCam IPQ1615 Possible terminations are terminal box or plug Figure 5 2 RoughCam IPQ1615 T10 VA2 3 K3 BOR2 N H xxx N T Figure 5 3 RoughCam IPQ1615 T10 VA2 3 K3 BOR2 N H xxx N P Video Tutorial...
Page 14: ...or PoE GND BN 8 0 32 mm2 Solid conductor GND SHD YE GN PE 2 5 mm2 Flex Table 5 2 Wire assignment of terminal box without heater The pin assignment of the ASKD02 T is executed in accordance with the standard EIA TIA 568B for 100BaseTX and 24VDC as follows Camera T568B Colour ASKD02 T IEC60757 Terminal box Cross sectional surface Comment Reinforcement YE GN PE 2 5 mm2 Flex Tx WH OG 1 0 26 mm2 Solid ...
Page 15: ...2 L 24VDC L BU 10 1 5 mm2 L 24VDC PE YE GN PE 1 5 mm2 PE Table 5 4 Wire assignment of terminal box integrated heater The pin assignment of the ASKDP03 T is executed in accordance with the standard EIA TIA 568B for 100BaseTX and 24VDC as follows Camera T568B Colour ASKDP03 T IEC60757 Terminal box Cross sectional surface Comment Reinforcement YE GN PE 2 5 mm2 Flex Tx WH OG 1 0 26 mm2 Solid conductor...
Page 16: ...Doc ID 210222 PT10BA ES RoughCam IPQ1615_en_rev 00 docx Page 16 of 28 Figure 5 5 Sample circuit of terminal box without heater RoughCam IPQ1645 SKD01 T SKD01 T ...
Page 17: ...Doc ID 210222 PT10BA ES RoughCam IPQ1615_en_rev 00 docx Page 17 of 28 Figure 5 6 Sample circuit of terminal box heater integrated Figure 5 7 Photo of the wired terminal box RoughCam IPQ1645 ...
Page 18: ...1 Fusing PoE power supply requires no fuses The power supply fusing depends on the cable cross section and length Attention Recommendation for fusing relates to 40W 24VDC at 100 meters and 1 5 mm2 Attention When the heating switches on high current peaks occur Use slow blow fuses Attention Please pay attention to the national and international regulations re garding selectivity and line protection...
Page 19: ...ady be supplied with power hence there is no power ON priority which has to be observed Attention Use appropriate RJ45 plugs Check the cable shielding cross section and the outside diameter Attention It is imperative to ensure a correct routing of the individual wires ac cording to the EIA TIA 568B Attention Finally check your network installation with a Class D Link Test Detailed instructions on ...
Page 20: ...th this User Manual and other ap plicable regulations Attention Incorrect installation or operation of the camera may lead to a loss of warranty Attention Do not switch on the camera at temperatures below 0 C 6 Working inside the camera housing The customer may open the housing only if it is absolutely necessary Only exchanging the SD memory card or a hardware reset are reasons for this 6 1 Prepar...
Page 21: ... 2 2 similar illustration To open the stainless steel housing T11 VA2 3 x x of RoughCam IPQ1615 loosen the eight cylinder head hexagon screws DIN 912 ISO 4762 together with their spring rings DIN 127A on the rear side of the cable and power supply flange see Figure 6 3 Cau tion do not touch the screw threads with your skin or clothes On the threads there is LOCTITE 243 chemical basis is dimethacry...
Page 22: ...ays and terminal block are fixed on the cable and supply flange Dealing with these components too you have to work very carefully and precisely in order to avoid canting and damage to the in built components Caution do not touch the cylindrical fit surface with your skin or clothes On the surface there is oil lubricating paste to protect the surface against fretting corrosion and mechanical stress...
Page 23: ...n the memory card can also be accessed via FTP server in the network If the memory card has to be replaced by the user it should be as far as possible empty and pre formatted with an ext4 or vFAT file system When touching electrical components observe potential equalization grounding of the body carry electrostatic discharge clothes a PE wristband etc 1 Status LED 2 Lens 3 Network connection port ...
Page 24: ...to re install the current firmware or to install an update see Chapter 7 6 5 Closing of the pressure resistant housing For closing the housing proceed in reverse order as when opening Use exclusively orig inal screws included in the supply The cable and power supply flange K3 is fixed by 8 cylinder head screws M4 0 0 7 ISO metric right turning with 30 mm thread length DIN 912 ISO 4762 grade 6g Mat...
Page 25: ...h a case the applicable settings have to be carried out inside the menu System Options Advanced Plain Config User root Password root 7 1 Browser Support A list of the currently supported web browsers operating systems required add ons etc can be viewed at http www axis com techsup cam_servers tech_notes browsers htm 7 2 Assigning the IP address The RoughCam IPQ1615 is intended for use in an Ethern...
Page 26: ...enance intervals are specific to the individual devices The operating company has to determine these intervals depending on the application parameters If maintenance measures are necessary they have to be initiated and or executed Repairs may only be carried out with original parts of SAMCON Prozessleittechnik GmbH In case of doubt send the part in question back to SAMCON Prozessleittechnik GmbH R...
Page 27: ...s 3D models All drawings 3D models certificates and other information are available in the download area of the product page on our website https www samcon eu en products roughcam roughcam ipq1615 If you wish additional technical information please contact us at support samcon eu ...
Page 28: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31 ...