Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 27 of 36
Figure 6-3 Opening the ExCam IPM2036 (similar illustration)
Carefully pull out the cable and supply flange to the rear, as straight as possible. Be-
cause of negative pressure, it may be difficult to remove the flange. The cylindrical clear-
ance fit (H8f7 - DIN ISO 286) of the camera body and flange may not be tilted! Risk of
damage to the flame-proof gap (DIN EN 60079-1:2012)!
Attention: The mounting adapter with the housing’s PTC heater, camera module and op-
tics, as well as the temperature control, and (if applicable) auxiliary relays and terminal
block are fixed on the cable and supply flange. Dealing with these components, too, you
have to work very carefully and precisely in order to avoid canting and damage to the in-
built components! Caution: do not touch the cylindrical fit surface with your skin or
clothes! On the surface, there is oil lubricating paste to protect the surface against fretting
corrosion and mechanical stresses.
When you open the housing, pay attention that you do not damage the GYLON® flat seal
(blue, RAL5012) and do not make it dirty! The flat gasket is loosely attached to the cable
and power supply flange. It is fixed only by the bolted connections!
Attention!
Pay attention not to damage the surface of the drill hole and the shaft
(fitting) of the flame-proof gap.
Attention!
Pay attention not to damage the housing seals. Keep them clean!