Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 26 of 36
Figure 6-1 Removing the weather protection roof (1/2) (this illustration is an example)
Figure 6-2 Removing the weather protection roof (2/2) (similar illustration)
To open the stainless-steel housing (T07 VA2.1.x.x) of ExCam IPM2036, loosen the eight
cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings (DIN
127A) on the rear side of the cable and power supply flange (see Figure 6-3). Caution: do
not touch the screw threads with your skin or clothes! On the threads, there is LOCTITE®
243™ (chemical basis is dimethacrylate ester) applied to prevent the bolted connection
from unintentional loosening because of impacts and vibrations and to seal them tightly.
It is not permitted for the customer to open the front-side sight glass flange! There is no
need of such an action.