Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 19 of 36
Attention!
Introduce the foiling up to about 15 mm close to the terminals, in order
to prevent alien crosstalk. Make sure that the foiling cannot cause any
short circuit of the data pairs!
Attention!
Bring the twisted pair composite up to about 10 mm close to the ter-
minals, in order to ensure interference immunity.
Attention!
Use only terminals approved by SAMCON.
Attention!
Finally, check your network installation with a Class-D Link Test.
5.3
External connection and protection
There are several options of routing the ExTB-2/3 terminal box to a safe area:
5.3.1
Direct routing from the ExTB-3 into the safe area
Figure 5-8 ExTB-3 -> Safe area
In the case of direct routing from ExTB-2/3 to the safe area, the voltage signal is led from
the safe area to the terminal box. Please observe the terminal box assignment, as de-
scribed above.
Switch/
PoE
15W