Doc.-ID: 220607-PT08BA-ES-ExCam IPM2036_en_rev.00.docx, Page 11 of 36 

Safety Instructions 

 

Please absolutely observe the installation instruc

tion’s safety 

directions of the T08 ExCam series! 

 
Quick link: 

https://www.samcon.eu/fileadmin/documents/en/22-Ex-Network-Cameras/ExCam-Series-T08-EX-Installation-Manual-2020.pdf 

 

It is absolutely mandatory to adhere to the national safety regulations and regula-
tions for prevention of accidents, as well as to the safety instructions given below 
in this User Manual! 

 

Attention! 
Cameras of type T08 ExCam are not suitable for use in zones 0 and 20. 
The ambient temperature, temperature class and explosion group writ-
ten  on  the  enclosure  nameplate  must  be  absolutely  adhered  to!  The 
customer  is  not  allowed  to  make  any  alterations  of  the  camera!  The 
camera must be operated in a proper and sound condition and only in 
the way intended. 

 

Attention! 
Repairs may only be carried out by using original parts from the man-
ufacturer.  Repairs  which  affect  the  explosion  protection  may  only  be 
carried  out  in  accordance  with  the  nationally  applied  regulations  and 
exclusively by the manufacturer. 

 

Attention! 
Prior to installation, take external sources of heat or cold into account! 
The  temperature ranges prescribed for storage,  transport and operat-
ing must be adhered to! 

 

Attention! 
Adhere to the warnings given on the nameplate: 

 

“WARNING – DO NOT OPEN IN HAZARD AREAS“ 

 

Using the camera in explosion-protected areas with regard to tempera-
ture and dust layers is defined in the respective national regulations. 

 

When installing the ExCam, adhere to the requirements of the EN/IEC 
60079-14. 

 

 

Summary of Contents for ExCam IPM2036

Page 1: ...ExCam IPM2036 User Manual...

Page 2: ...tential equalization 14 5 2 Connection work at the device terminal box and fuses 15 5 3 External connection and protection 19 5 3 1 Direct routing from the ExTB 3 into the safe area 19 5 3 2 Routing v...

Page 3: ...t of terminal box ExTB 2 18 Figure 5 7 Connection to the terminal box 18 Figure 5 8 ExTB 3 Safe area 19 Figure 5 9 ExTB 3 ExConnection Rail 20 Figure 5 10 Ex d cable selection 21 Figure 5 11 Barrier g...

Page 4: ...e attached a very high importance to safety me chanical precision and high quality of stainless steel 2 Technical data 2 1 Explosion protection Identification marks acc to Directive 2014 34 EU II 2G z...

Page 5: ...xplanations 1 ExCam IPM2036 Functional camera description of the ExCam Series technical data specification of the individual camera module 2 T08 SAMCON Production Type 08 3 VA2 1 K1 BOR T07 ex d housi...

Page 6: ...lens 3 6mm F1 8 IR 85 T08 VA2 1 K1 BOR X X XXX X X 056 normal Megapixel lens 6 0mm F1 9 IR 56 T08 VA2 1 K1 BOR X X XXX X X 041 tele Megapixel lens 8 0mm F1 8 IR 41 2 3 Electrical parameters of the ca...

Page 7: ...AWG23 1 CAT 6 Properties PUR halogen free flame retardant UV resistant chemical resistance shielded Quick link https www samcon eu fileadmin documents en 60 Assembling 26mounting SKD02 T_Datasheet pd...

Page 8: ...sembling 26mounting SKD05 HT_Datasheet pdf Figure 2 3 Sectional view of SKD05 HT 2 5 Video technical characteristics We use the AXIS M2036 LE Network Camera in a pressure resistant enclosure For de ta...

Page 9: ...e the Thresold slider towards Bright or Dark 3 To use the built in IR light oft he camera when the camera is in night mode Acti vate Allow IR illumination and Synchronize IR illumination 4 Tip Set the...

Page 10: ...lumination can only be used up to a maximum object distance of 2 0 m In addition the quality of the image is strongly influenced by the resulting reflections and the object to be observed is no longer...

Page 11: ...adhered to The customer is not allowed to make any alterations of the camera The camera must be operated in a proper and sound condition and only in the way intended Attention Repairs may only be carr...

Page 12: ...the best image quality delivered by the network camera plan the installation site carefully consider light conditions object distance or size angle and minimum object distance to the focus Use appropr...

Page 13: ...sories Wall bracket WMB WALL MOUNT WMB VA2 1 2 2 Wall bracket for cameras of the T08 VA2 1 Series Suitable for hanging the cameras on walls Material Stainless steel 1 4404 Load bearing 25 kg Dimension...

Page 14: ...e A SKD02 T models without cooling or type SKD05 HT models with cool Jacket The maximum transmission range from the camera to the next active network interface is 100 meters without cool Jacket or 60...

Page 15: ...ly PoE IEEE 802 3at type 2 class 4 Reference power 48 V DC 44 54 V DC Maximum power input 25 5 W 30 W from the PSD Typical power input 12 95 W Power supply for the camera PoE Voltage supply PoE IEEE 8...

Page 16: ...ever open the Ex e terminal box under voltage Attention Adhere to the international installation regulations for connection chambers with increased safety Ex e Attention Adhere to attached separate Us...

Page 17: ...ce Comment Reinforcement YE GN PE 2 5 mm2 Flex Tx WH OG 1 0 26 mm2 Solid conductor Tx OG 2 0 26 mm2 Solid conductor Rx WH GN 3 0 26 mm2 Solid conductor Rx GN 4 0 26 mm2 Solid conductor PoE 48 VDC WH B...

Page 18: ...607 PT08BA ES ExCam IPM2036_en_rev 00 docx Page 18 of 36 Figure 5 6 Sample circuit of terminal box ExTB 2 Figure 5 7 Connection to the terminal box ExCam IPM2036 SKD02 T SKD02 T PoE 802 3af 100 BASE T...

Page 19: ...re interference immunity Attention Use only terminals approved by SAMCON Attention Finally check your network installation with a Class D Link Test 5 3 External connection and protection There are sev...

Page 20: ...must comply with national and international regulations 5 3 2 Routing via ExConnection Rail optional accessories Figure 5 9 ExTB 3 ExConnection Rail In the case of routing the ExTB 2 3 into an ExConn...

Page 21: ...ent cross section The cable pro tection must comply with national and international regulations For non binding configuration and planning guidelines please visit our website Perhaps our video will he...

Page 22: ...utorial SAMCON 02 Mounting and installing Ex d barrier glands to ExConnection Rails https go samcon eu v02 Figure 5 11 Barrier gland 5 3 4 Fusing PoE power supply requires no fuses The power supply fu...

Page 23: ...upplied with power hence there is no power ON priority which has to be observed Attention Use appropriate RJ45 plugs Check the cable shielding cross section and the outside diameter Attention It is im...

Page 24: ...orm all tests as indicated by the na tional regulations Furthermore check the correct function and instal lation of the device in accordance with this User Manual and other ap plicable regulations Att...

Page 25: ...explosive atmosphere 6 2 Opening the pressure resistant housing WARNING MAY NOT BE OPENED IN HAZARD AREAS Note Depending on classification of hazard areas it is imperative to obtain a work approval fi...

Page 26: ...xagon screws DIN 912 ISO 4762 together with their spring rings DIN 127A on the rear side of the cable and power supply flange see Figure 6 3 Caution do not touch the screw threads with your skin or cl...

Page 27: ...ock are fixed on the cable and supply flange Dealing with these components too you have to work very carefully and precisely in order to avoid canting and damage to the in built components Caution do...

Page 28: ...and deleted via the web interface They are also availa ble in a download list Moreover the videos available in the memory card can also be accessed via FTP server in the network If the memory card ha...

Page 29: ...rdware reset is not satisfacto ry or the network camera shows serious conflicts or does not work as usual errors in the browser visualisation frozen images control commands no longer pro cessed slowin...

Page 30: ...Then re grease it with lubricant suitable for this specific application e g Mo lykote P 40 gel for standard applications or special grease OKS 403 in the event of heavy seawater influence The screwed...

Page 31: ...particularly in surroundings with fluorescent tubes In such a case the applicable settings have to be carried out inside the menu System Options Advanced Plain Config User root Password root 7 1 Brows...

Page 32: ...r clear device identification are also detected and dis played Figure 7 1 Axis IP Utility 7 3 Password Identification The following user name is set at the factory root The following password is set a...

Page 33: ...ance with nationally applied regulations by SAMCON Prozessleittechnik GmbH or by an au thorised electrical technician authorised by SAMCON Prozessleittechnik GmbH Rebuild ing of or alterations to the...

Page 34: ...u wish additional technical information please contact us at support samcon eu 11 Certificates and further documentation Certificates and further documentation are available in the download area at th...

Page 35: ...Doc ID 220607 PT08BA ES ExCam IPM2036_en_rev 00 docx Page 35 of 36 12 Notes...

Page 36: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31...