RECD ON ACCT 1-3 - Function Key Options
Options - Program 70 (P-Mode)
Address OPTION
VALUE = SUM
Key is inactive?
Yes = 1
No = 0
Key is active in X control lock position
only?
Yes = 2
No = 0
N1
Validation is compulsory?
Yes = 4
No = 0
SCALE - Function Key Options
Options - Program 70 (P-Mode)
Address OPTION
VALUE = SUM
Key is inactive?
Yes = 1
No = 0
Key is active in
X
control lock position
only?
Yes = 2
No = 0
N1
Allow manual entry of weight?
Yes = 4
No = 0
Subtract tare weight on the scale entry?
Yes = 1
No = 0
Not Used
0
N2
Scaleable items can be open price or
scaleable entry.
Yes = 4
No = 0
N3
Weight symbol for manual entry is:
Lb = 0
Kg = 1
Oz = 2
R/A
CASH
Repeat for another
function
N1
SUBTL
0
7
SCALE
CASH
Repeat for another function
N1
SUBTL
0
7
N2
N3