AIS 3410, Electronics Unit
ED3047G842 / 01 (2009-08)
Technical Manual
6 Repair/Maintenance
6.3 Software Update
t_ue_e07.fm / 27.08.09
56
Connection at the Electronics Unit
The cable must be connected to the serial service interface of the computer and to the connector on the
top of the Electronics Unit’s port
Fig. 6-6
Service Interface
6.3.4 Software Update by means of a Laptop
1.
Disconnect the Electronics Unit from the power supply for about 5 s.
2.
Connect the power supply and wait about 2 minutes until the Electronics Unit has been restarted.
3.
Connect the update cable before the update software is started.
4.
Download the update from the SAM-CMIS system (see
), unzip the file and save the
unzipped directory structure to the hard disk or on a CD ROM.
5.
To start the update software open the directory of the software version which shall be installed
(usually the newest version; for details see the readme file)
DOS command line:
CD X:\AIS\ElectronicsUnit3410\BuildNNN_YYYYMMDD\root
(DRIVE X name of the drive, NNN = release of the software, YYYY=year, MM=month, DD=day)
Type aisupdate.exe to start the software.
Type
aisupdate.exe
on the command line to start the program.
Windows Explorer:
Open the Windows Explorer and select the drive with the update directory.
Select the following path by clicking twice on the directory names:
AIS -> ElectronicsUnit3410
-> BuildNNN_YYYY_MM_DD -> root
Start the program
aisupdate.exe
by clicking twice on the corresponding icon.
6.
Click the
Start Update
button.
If a failure message appears, press the
COM 1
button to switch the serial port used by the program
to COM 2.
Service Interface
z_
ue
_0
52.
jp