74 / 80
15.4
Connections
Appliance foot
View from below
Water connection G 3/4
Electrical connection and connection for
demand management system or energy
optimisation system
Equipotential bond
ing connection
Drain diameter 20 mm
Type plate
Steam generator air valve and overflow
relief valve
Rear:
network
connection
(Ethernet/LAN)
15.5
Water connection
● Observe the regulations issued by the local water utility company.
● Do not connect to a hot water supply, instantaneous water heater or unpressurised hot water ap
pliances.
● The appliance must be operated with cold drinking water.
● A water tap and a water filter (50 microns) must be installed in an easily accessible position ups
tream of the appliance.
● Water pressure (cold water):
−
At least 200 kPa (2 bar), dynamic: the working pressure must not drop below 200 kPa due to
additional consumers – install a separate water inlet or pressure booster pump if required.
−
Maximum 350 kPa (3.5 bar), static: at pressures above 350 kPa (3.5 bar), install a pressure
regulator upstream of the appliance.
● The appliance has a built-in water softener. This must be configured by the authorised Customer
Service. For instructions about regenerating the water softener, see page 65 , section 12.
● As standard, appliances are supplied prepared for connection to a drinking water supply. If the
appliance needs to be connected to an osmosis filter system:
−
Special appliance settings must be made by the authorised Customer Service
−
The conductivity of the water produced by the osmosis filter system must be between 2 and
50 μS/cm.
● Always use connecting hoses that are tested, pressure-resistant, flexible, food-grade quality and
certified. Maximum length of connecting hose 2000 mm.
● The supply hose must not be kinked or squashed flat anywhere along its length.
● Flush out the water supply line and the supply hose before connecting.
● Check that all connections are watertight.