Operating Instructions
87 / 92
13.7.6 Cleaning the control/display panel and the key "On/Off"
D
The control/display panel and the "On/Off" button have to be free of any detergent residues after
cleaning.
D
The mixture of detergent residues and precipitating humidity affect the reaction of the control/display
panel.
D
Remove residual cleaning agent from the control/display panel only when switched off.
.
Then clean the control/display panel with warm water and cotton cloths.
.
As required, use special cleaning agent manufactured for Touchscreens (Touchpad) and that prevents
condensation of steam.
13.8
Decalcifying the cooking chamber
No scale may develop in the cooking chamber if the appliance has been properly connected to a water
softening system. If scale still forms, the water softening system must be inspected and the cooking cham
ber decalcified.
.
Use the decalcifying agent according to the manufacturer's instructions in the cooking chamber.
13.9
Cancelling automatic cleaning
Automatic cleaning should be cancelled only in exceptional situations!
1
.
Tap the "Start/Stop" key.
D
Automatic cleaning is stopped.
D
The cleaning system still contains cleaning agent
after stopping the cleaning process. A cooking pro
cess can therefore only be started after an automatic
rinse process was first performed.
D
If there is a power cut during automatic cleaning, a
rinsing operation will be required.
2
Rinsing process after cancellation
A rinsing process must be performed if the automatic
cleaning of the cooking chamber was interrupted.
Duration approx. 15 to 20 minutes (rinsing process takes
place with rinse-aid if a rinse-aid canister is connected)
It is not possible to cancel rinsing by tapping the "Start/
Stop" key during the process.
Starting the rinse process, refer to Page 81 Chap
ter 13.6.3 (Figure 2)
13.10 Cleaning of the condensate cover (optional)
Important! Condensation covers must be cleaned regularly!
.
Use a vacuum cleaner to clean the air intake and exhaust vents periodically.
D
Depending of the degree of contamination, the condensation cover (optional) should be cleaned by an
authorised customer service technician at least once a year!