Note:
If all valve dimensions are consistent with those given below, then the TRV
head will be compatible. If there are dimension differences, contact us or the installer
to find replacement for the valve.
Note:
One thermostat can control up to 6 TRV heads within one room.
Quick Guide
Importer:
SALUS Controls plc
Salus House, Dodworth Business Park
Whinby Road, Barnsley S75 3SP,
United Kingdom
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS
Controls plc reserve the right to change specification, design and
materials of products listed in this brochure without prior notice.
IV 2018
Introduction
The TRV thermostatic head is controlled through wireless ZigBee
communication protocol. It can replace classic, manual thermostatic head in a
very quick and easy way. For proper operation of the TRV head it is necessary
to synchronize it correctly with wireless thermostat using the CO10RF
coordinator or UGE600 Internet gateway (all devices are sold separately). TRV
head paired with the iT600RF series digital thermostats (e.g. VS10RF / VS20RF
/ HTRS-RF (30) / HTRP-RF (50) / TS600) provides comfort within the whole
room, not just in the radiator area.
Product Compliance
This product complies with the essential requirements and other relevant
provisions of Directives 2014/53/EU, 2014/30/EU, 2011/65/EU. The full text
of the EU Declaration of Conformity is available at the following internet
address: www.saluslegal.com.
Safety Information
Use in accordance to national and EU regulations. Use the device as intended,
keeping it in dry condition. Product for indoor use only. Installation must be
carried out by a qualified person in accordance to national and EU regulations.
The TRV head is a modulating device. This means that the valve can be
gradually closed or opened, depending on the current room temperature
measured by thermostat and the setpoint temperature.
For MMA or Herz M28x1,5 thermostatic valves make
sure you have a metal washer as shown in the picture.
For a standard thermostatic valve with M30x1,5
thread (e.g. Oventrop, Honeywell, TA, Heimeier)
TRV10RFM head installation looks like as shown in
the picture.
When mounting the TRV10RFM head on the Danfoss
RA valve (see picture), please use the RA adapter
included with the head. However, to install the
TRV10RAM head it is necessary to use the Allen
Wrench key.
NOTE:
For the Comap valve with M28 thread you do
not need to mount a metal washer.
TRV head is compatible with most of the thermostatic valves available on
the market, however, before installation, please check whether the valve is
suitable for use with the TRV head.
Put the RA
adapter on the
Danfoss RA
valve.
Place TRV
head on the
valve.
Tight RA
adapter
and screw
TRV10RFM
head on it.
Assembly to
the valve and
tighten only
2 out of 4
screws.
Measure the thread diameter.
Thread for the TRV10RFM must
have a diameter of 30 mm, and for
the TRV28RFM - 28 mm.
Remove the battery cover located on
the side of the device.
When the LED diode lights up
continuously with a
red
color,
screw the TRV on the valve.
When the LED goes out and TRV
head does not make any sounds,
adaptation process is finished.
Equipment is ready for pairing
with thermostat.
Press any button to start the
adaptation process of TRV head with
thermostatic valve. The process takes
up to 5 minutes.
Insert the batteries according to the
markings and close the battery cover.
The LED will start blinking
green
/
red
informing about the software
version.
Measure the height of the valve’s
pin when it is in the open position.
For TRV10RFM valve’s pin height
should be 13-15 mm, while for
TRV28RFM 10-11 mm.
dismantle the old radiator
head
radiator
valve
To achieve the best possible results in cooperation between the thermostat
and the heating source, it is recommended to use the RX10RF receiver.
RX10RF turns on the heat source depending on the demand signal sent by
thermostat. More informations about RX10RF receiver is included in its user
manual.
1
2
3
4
Opening the head / indication
of the device status
Closing the head / indication
vof the device status
Pairing button
LED diode (indicates device status)
Box Content
TRV28RFM head installation
User interface
Buttons function
TRV10RFM head installation
TRV head setup
TRV head installation on the Danfoss RA valve
General informations
Checking compatibility with the heating system
TRV10RFM
adapter
Manual
instruction
2 x AA batteries
metal
washer
Allen Wrench key
TRV10RFM
Each box additionally contains:
TRV28RFM
TRV10RAM
TRV28RFM
TRV10RAM
+
+
OR
1
2
mm
10
20
30
3
mm
10
20
30
40
50
TRV10RFM
HEAD MOUNTING
TRV10RAM
HEAD MOUNTING
1
2
3
4
5
6
To do this...
Press the...
...pair with thermostat
...pairing button for 10 seconds.
...lock/unlock the buttons
...pairing and close buttons together
for 5 seconds.
...manually open the valve
...opening button for 5 seconds.
...manually close the valve
...closing button for 5 seconds.
...enter the automatic mode
...shortly pairing button
...remove the head from the
ZigBee network
...pairing button for 10 seconds
...restore factory default settings
...Open , pairing , and close
buttons together for 5 seconds
Wireless, thermostatic TRV head
Manual for models: TRV10RFM, TRV10RAM i TRV28RFM
Note:
Buttons lock itself automatically after 5 minutes from the last one keystroke.