Instruction Manual

Model No’s PH60/PH60-1/PH60-C

PI

Control

Programmable Thermostatic
Radiator Valve Control Head

Salus PH60PI  Manual 014_89  17/05/2013  11:58  Page 1

Summary of Contents for PH60

Page 1: ...Instruction Manual Model No s PH60 PH60 1 PH60 C PI Control Programmable Thermostatic Radiator Valve Control Head...

Page 2: ...SAFETY INFORMATION These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only and must not be used with any other make or model These instructions shou...

Page 3: ...d with an easy to read Liquid Crystal Display LCD and a five key operating panel which is coupled with a unique smart design that makes the PH60 easy to programme and operate PI Control The SALUS PH60...

Page 4: ...rrectlyas indicated Installation of the batteries is a straightforward operation Remove end cap from the PH60 body as shown in this picture and insert the batteries please make sure that the batteries...

Page 5: ...in Once the control pin is fully retracted the display stops flashing and the display will indicate the valve is open Install the TRV to the valve To move to the next stage press any key The flashing...

Page 6: ...the problem still exists an error code will be displayed Error Code Description Er1 Stroke too short During the P2 adaptation stage the pin stopped extending before reaching its minimum controllable p...

Page 7: ...the adaptation process It is also possible to enter ADAPTATION mode manually if the PH60 is in NORMAL mode This is done by pressing the SET key until AdAP is shown on the display Releasing the SET ke...

Page 8: ...isplays The status indicator symbols and their meanings are shown in the following table User Control Function Summary Indicator Description Function 1 2 3 4 5 6 7 Day of Week In NORMAL mode indicates...

Page 9: ...ened A closed valve animation is shown when the valve is closed Indicator flashes when the valve is opening Low Battery Indicator flashes when the Indicator battery voltage is low Programme In PROGRAM...

Page 10: ...is Econ Party In NORMAL mode indicates Temperature the set temperature is Party Mode In MANUAL mode indicates the Indicator set temperature is Party Holiday In NORMAL mode indicates Temperature the s...

Page 11: ...de indicates the Profile Indicator controller is running in AUTO Programme control mode In PROGRAMME mode indicates the profile of the selected day In the PROGRAMME COPY mode it indicates the program...

Page 12: ...selection SELECT Selects item when in SET mode AUTO MANUAL In NORMAL mode press to choose the AUTO programme or any of the MANUAL control modes Reset Button Press and hold for more than one second to...

Page 13: ...the bottom of the display shows the PH60 is in AUTO mode The Econ indicator shows the PH60 set temperature mode is Econ Auto and Manual Control Modes When the PH60 is operating in AUTO mode TRV contro...

Page 14: ...e indicator is not displayed and the set temperature is fixed to the temperature selected by the user The images below show the PH60 operation in MANUAL mode with the set temperature in Comfort Econ P...

Page 15: ...iday Manual Frost Manual Off Auto Press the SET key or wait for 8 seconds to return to NORMAL mode and the PH60 will start to operate in the new mode When choosing the control mode you can use the or...

Page 16: ...ting mode The display will change to show Pro Press and hold the SET key for 7 seconds to enter the programme copy mode The display will change to show Pro and the copy icon Press and hold the SET key...

Page 17: ...to change the setting Press the SELECT key to select the day press the or keys to change the setting Pressing the SET key or not pressing any keys for 30 seconds will return the PH60 to NORMAL mode Pr...

Page 18: ...above the time between 0600 to 2200 will represent a Comfort setting High set point temperature The blank areas will represent an Econ setting Low set point temperature Please note Econ temperature c...

Page 19: ...ings are adjusted as follows The PH60 has 5 preset set temperature modes No Programme Description 1 Comfort A warm comfortable setting Adjustable between 7 30 C 2 Econ A lower setting than Comfort to...

Page 20: ...3 4 5 6 7 1 5 6 7 1 7 Press SET again to return to NORMAL mode 1 5 6 7 and 1 7 are called day groups all the days included are programmed together The programming method is the same as single day pro...

Page 21: ...dicator is also displayed with an animated pointer pointing towards the clipboard Press the or keys to select and copy other days then press the SET key to go to the next screen Initially the same day...

Page 22: ...Pressing the or keys will allow you to change the setting Pressing the SET key will confirm the choice and move to the next screen This is adjusted and set automatically in adaptive mode see AdAP page...

Page 23: ...SET key will confirm the choice and move to the next screen The fifth option is the Limescale Protection LInE and the current setting is displayed Pressing the or keys will allow you to change the se...

Page 24: ...is in NORMAL mode This is done by pressing the SET key until AdAP is shown on the display Releasing the SET key will start the adaptation process If an error is displayed during the manually selected...

Page 25: ...e TRV is displayed on the PH60 is shown by the valve status indicator Display Status When the TRV is closed the PH60 will display a closed valve indicator When the TRV is open the PH60 will display a...

Page 26: ...operated for long periods limescale deposits can build up in the valve and prevent correct operation The PH60 has an inbuilt limescale protection mode to prevent this problem When limescale protection...

Page 27: ...PH60 will automatically monitor the room temperature If the temperature falls quickly within a user selectable setting of 1 0 1 5 or 2 5 C the PH60 will enter Open Window mode and close the TRV If the...

Page 28: ...fault Control Mode Auto Room Temperature Depends on current room temperature Room Temperature Offset 0 0 C Set Temperature Depends on current programme Comfort Set Temperature 21 C Econ Set Temperatur...

Page 29: ...settings check that the keylock mode is not turned on To disable the keylock press and holding the SELECT key again for three seconds Temporary Override Mode When the PH60 is in AUTO mode the user ca...

Page 30: ...attery level is low When the low battery indicator is displayed you should replace the batteries as soon as possible The PH60 will also monitor the maximum motor speed achieved when the valve is being...

Page 31: ...perature Off mode is generally used when heating is not needed for example in the summer When Off mode is operating it will be indicated on the display as shown below If limescale protection is enable...

Page 32: ...erature is equal to 3 of your heating costs MAINTENANCE The PH60 programmable TRV controller requires no special maintenance Periodically the outer casing can be wiped clean using a dry cloth please D...

Page 33: ...per month Programming Programming Modes User selectable for 7 day individual 5 2 or 7 day options Hourly programming to Comfort or Econ set points Group programming function Override Facility User se...

Page 34: ...con 7 30 C 0 5 C Party 15 30 C 0 5 C Holiday 7 15 C 0 5 C Frost 4 7 C 0 5 C Power Supply Power Source 2 x AA LR6 alkaline batteries Battery Life Approximately 1 year Memory and Operating Backup Memory...

Page 35: ...specification for a period of two years from the date of purchase Salus Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product PH60 Warran...