![Salus PCSol 201 Installation And Operation Manual Download Page 32](http://html1.mh-extra.com/html/salus/pcsol-201/pcsol-201_installation-and-operation-manual_3644550032.webp)
32
Table
of
sensor
resistance
against
temperature:
temperature
resistance
-
25 ºC
-
20 ºC
-
10 ºC
0 ºC
10 ºC
20 ºC
25 ºC
30 ºC
40 ºC
50 ºC
60 ºC
70 ºC
80 ºC
90 ºC
100 ºC
110 ºC
120 ºC
130 ºC
140 ºC
150 ºC
160 ºC
170 ºC
901,9 Ω
921,6 Ω
960,9 Ω
1000,0 Ω
1039,0 Ω
1077,9 Ω
1097,3 Ω
1116,7 Ω
1155,4 Ω
1194,0 Ω
1232,4 Ω
1270,7 Ω
1309,0 Ω
1347,1 Ω
1385,0 Ω
1422,9 Ω
1460,7 Ω
1498,3 Ω
1535,8 Ω
1573,2 Ω
1610,5 Ω
1647,7 Ω
Fig. 16.8 Connection of temperature sensors*
*Sensor’s function may differ from the drawing
depending on selected scheme
16.2.5.
Temperature sensor installation
Temperature sensors are equipped with
brass coat with diameter of 6mm and 50mm
long. They should be installed possibly close to
the temperature measurement point. The sensors
must be installed so that the brass coat is
thermally insulated from the environment.
The collector temperature sensor must be
located in the collector tube possibly deep, as
this is conditional for correct measurement.
If you need mount your sensor on pipe surface
(e.g.
CH
temp. measurement), then the sensor
coat must be attached using a brace, and the
jointing point to insulate e.g. with foam or other
insulating material, so that there is sufficient
temperature convection to the sensor.
Fig. 16.9 Sensor installation on pipe surface
16.2.6.
Room
temperature
sensor
installation
The room temperature sensor type
CT7
is
only used in the
M
scheme.
Controller cooperate with
CT7
type room
temperature sensor. The sensor should be
connected to the
T3
input. Use a cable with a
cross-section of at least 0,25mm
2
to connect
sensor. Recommended cross-section is
0,5mm
2
.
Cable should not be longer than
20m
.
Fig. 16.10 Cable socket and how to close the CT7
sensor housing
Sensor cables should be separated from power
cables (~230V). If not, incorrect temperature
readings can occur. Minimum distance between
sensor cables and power cables should be at
least 100mm.
In order to guarantee a maximum operation
efficiency
of
the
regulator,
follow
the
recommendations concerning a place of sensor
assembly:
Sensor should be assembled on a height
app. 1,5m over the floor level.
Avoid places which are strongly sunlit,
close to heating devices, in direct vicinity
of
doors
and
windows,
where
a
S
en
so
r
T
1
[+
]
S
en
so
r
T
1
[
-]
S
en
so
r
T
2
[+
]
S
en
so
r
T
2
[
-]
S
en
so
r
T
3
[+
]
S
en
so
r
T
3
[
-]
S
en
so
r
T
4
[+
]
S
en
so
r
T
4
[
-]
Insulating
material
Pipe
Brace