TECHNICAL DATA
Measurement inputs
(low-voltage)
Collector temperature input (T1)
Temperature input (T2)
Temperature input (T3)
Temperature input (T4)
Other inputs/outputs:
(low-voltage)
Output (H) 5-6V/0,1A (DC)
Output PWM for
controlling the solar pump
(only P1)
PWM freguency signal: 200Hz
Signal level: 5V
Digital: 5÷100%
High-voltage outputs
:
Output P1: 230V/ max 0,5A (AC)
Output P2: 230V/ max 0,5A (AC)
Power supply:
Controller: 230V(AC), 50Hz. I=1.02A*
Load ability P1,P2:
not more than 0.5A(AC)/output
Operating conditions
0° ≤ Ta ≤ 40°C, humidity 10
-90%, without condensation
Protection degree
IP 20
Weight
~280g
Dimensions
WxHxL
* Power intake only by controller is 0.02A (1,5W)
Table of temperature measurement accuracy:
Internal structure
Pt1000 class B (CT6 and CT6w)
Temperature ranges
-
40÷0°C
0÷1
3
0°C
130
÷
180
°C
Accuracy*
±2
°
C
±1°C
±
2
°
C
Displayed range
T1 (T3
**
)
-39,9
÷
179.9
°C
T2, T3, T4
0,0
÷
99,9
°C
* at ambient temperature of 23°C
** in scheme H, L
16.
INSTALLATION
The controller is designed for operation in the
environment
where
only
dry
conductive
contaminations may be present (2 degree of
contamination according to PN-EN 60730-1).
In addition, the controller may not be used in
water condensation conditions and it may not be
exposed to water.
The unit software does not ensure
required protection level that must be
assured by external protections of the
solar system.
16.1.
Installation of the controller
The controller is designed for vertical wall-
mounted installation. External circuit wires are
supposed be lead on surface. Mounting hole
locations are presented as in the casing. Hole
spacing dimensions are presented also in Fig.
16.2
Wires that enter the controller must be
secured at entry locations.
Before
opening
the
unit
casing,
disconnect
power
supply.
The
unit
installation must be done at disconnected
voltage.
The unit has any fuse replaceable by the
installer or use. If the fuse was burnt
during installation or operation, it means
damage of the unit. Send the unit to
authorized service for repair.
Controller must be installed by qualified
and authorized technichian in accordance
with EN 60335-1 standard.
For how to open the unit casing see the picture
below.
Fig. 16.1 Casing opening