background image

Head Office: SALUS Controls plc

SALUS House

Dodworth Business Park South, 

Whinby Road, Dodworth,

Barnsley S75 3SP, UK.

T: +44 (0) 1226 323961

E: [email protected]

www.salus-controls.com

SALUS Controls is a member of the Computime Group.

Maintaining a policy of continuous product development SALUS Controls plc reserve 

the right to change specification, design and materials of products listed in this 

brochure without prior notice.

Introduction

1. Serial connector 

4. Power indicator 

5. NSB (Night Set Back reduction) function

2. Power Supply

3. Connection indicator

Wiring centre description

Product compliance

Technical Information

The KL04NSB is an easy to connect four zone extension for the KL08NSB wiring centre. It expands  

the system to up to12 zones in total

The Serial connector is used to connect the KL08NSN with the KL04NSB extension module to add 

functionality and support up to12 zones 

NSB function is activated in non-programmable Salus thermostats of the Expert NSB, HTR, BTR series 

via external signal. NSB 230 V signal (night-time temperature reduction) is sent via an external timer 

or programmable thermostat connected to the wiring centre. Non-programmable thermostats are 

receiving NSB signal and reducing setpoint temperature (by switching to eco mode). All thermostats 

have to be connected using a 4-wire cable (min. 4 x 0,75 m

2

, max. 4 x 1,5 m

2

).

One Master thermostat 

which is common for 

thermostats from Group 1, 

Group 2 and Group 3 (one 

programmable thermostat 

e.g. VS30, other thermostats 

are non-programmable e.g. 

VS35).

One external clock which is 

common for thermostats 

from Group 1, Group 2 

and Group 3 (one external 

clock + daily regulators e.g. 

VS35).

Three Master thermostats. 

One for Group 1 , one for 

Group 2 and one for Group 

3 (three programmable 

thermostats e.g. VS30, 

other thermostats are non-

programmable e.g., VS35).

Three external clocks. One 

for Group 1, one for Group 2 

and one for Group 3 (three 

external non-

programmable regulators 

e.g. VS35).

• OPTION 1

• OPTION 3

• OPTION 2

• OPTION 4

After successful connection of KL08NSB with KL04NSB extension module 

red

 LED will light 

up constantly.

After connecting of KL04NSB to the power supply, the Power 

red 

LED will light up.

This product complies with the essential requirements and other relevant provisions of the following 

EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU and RoHS directive 2011/65/EU.

The full text of the EU Declaration of Conformity is available at the following internet address: 

www.saluslegal.com.

Use in accordance with national and EU regulations. Device is intended for indoor use only in dry 

conditions. Product for indoor use only. Installation must be carried out by a qualified person in 

accordance to national and EU regulations.

Before attempting to setup and install, make sure that the devices is not connected to any power source. 

Installation must be carried out by a qualified person. Incorrect installation may cause damage to 

the devices. The KL04NSB should not be installed in areas where it may be exposed to water or damp 

conditions.

Safety information

Manual

Wiring centre extension for 4-zone UFH

Model: KL04NSB

1.  

Serial connector 

 

2.  

Power supply

 

3.  

Connection indicator  

4.  

Power indicator 

5.  

NSB function terminals

6.  

Actuators connection

7.  

Thermostats connection

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

1

3

4

5

7

6

2

group

 

iii

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

230 V AC

L

N

Power supply for wiring centre is 230 V ~ 50Hz.

Two wire installation should be made in accordance 

with the applicable regulations 

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

0

Off

1

2

3

4

Reset

KL08NSB

KL04NSB

L 1-4

jumpers

5-8 9-12

L 1-4

no jumpers

5-8 9-12

L 1-4

jumpers

5-8 9-12

L 1-4 5-8 9-12

Power Supply

230 V AC

Total Load Max

3 A

Outputs

Terminals for actuators (230 V)

Dimensions [mm]

163 x 85 x 67

VII 2018

Reviews: