Salus ARV10RFM-3 Manual Download Page 1

Wireless Radiator Valve 
Model ARV10RFM-3  

 

INTRODUCTION

 

The ARV10RFM-3 is a battery-powered, mini-size thermostatic 
radiator  valve  (TRV)  controller  using  the  ZigBee  wireless 
protocol. Simply replace the existing, passive head on the 
standard 30mm radiator valve with the AVA10M30RF (referred 
to  from  now  on  as  the  TRV).  This  allows  you  to  convert 
systems with one or two thermostat zones into individually 
controlled  zones.  Pair  up  to  6  TRVs  with  the  AWRT10RF 
wireless  thermostats.  The  SG888ZB  Gateway  creates  the 
Zigbee  network.  An  optional  AX10RF  Receiver  controller 
may be used to control the boiler.  

SYSTEM OVERVIEW 

 

The Universal Gateway SG888ZB creates the Zigbee network. 

 

The thermostat(s) and TRV(s) join the Zigbee network to control the radiator(s) 

 

Up to 6 TRVs may be paired with a single thermostat. 

 

If you are using an optional AX10RF Wireless Receiver to control the boiler: 

o

 

If  any  thermostat  calls  for  heat  or,  if  the  TRV  is  manually  opened,  the 
AX10RF will energize the boiler  

o

 

As each zone is satisfied, the associated TRV(s) will close.   

o

 

The AX10RF will energize the boiler until all zones are satisfied, and then 
turn-off. 

See AX10RF and AWRT10RF manuals for more additional information. 

CHECK COMPATIBILITY WITH THE RADIATOR VALVE 

The  SALUS  TRV  is  compatible  with  most  common  thermostatic  radiator  valves. 
Confirm dimensions 

 

Thread diameter is 30mm (1.18in) 

 

Valve pin length when open is between 13-16mm (0.51-0.62in) 

If the dimensions do not match, it is recommended you change the radiator valve  

If there are no threads near the valve pin (below), use the RA Adapter included with 
the TRV 

 

Slip the Adapter over the stem until it clicks in place  

 

Make certain the adapter is fully seated  

 

Tighten the collar screw

 

Joining the TRV 

The TRV will remain in the Joining mode for 10 minutes after the first-time power has 
been applied (out of the box) or it has been factory reset.   

Prior to inserting the batteries in the TRV, prepare the AWRT and the App for joining. 

1.

 

From the App 

1.1.

 

Click Devices on the top menu bar 

1.2.

 

Click Add Devices in the drop-down menu 

1.3.

 

Click Scan Devices on the new page that opens 

2.

 

With the AWRT 

2.1.

 

Insert the Batteries, the AWRT will go through its boot process 

2.2.

 

When the display shows 

PAIR? RLY_CTRL

, press the ^ arrow once to 

display 

PAIR? RDTR_VLV

 

2.3.

 

Press SELECT button the display will show 

JOINING---

with a timer 

counting down from

 

10:00

 

3.

 

With the TRV 

3.1.

 

Remove TRV from the box 

3.2.

 

Remove side battery door 

3.3.

 

Insert batteries, ensuring 
proper polarity 

3.4.

 

Replace cover 

3.5.

 

The LED will flash 

Orange

, two 

times, slowly 

3.6.

 

It will go through a sequence of 
rapid 

Red

 

and 

Green

 

flashes 

indicating the firmware versions (i.e. 14.4/6.3) 

3.7.

 

The LED will then flash 

Green

 

(0.5s on/0.5s off) to indicate it is in the 

Joining 

mode 

3.8.

 

Once the TRV Joins the network and Pairs with the AWRT, it will begin the 
Adaptation process by retracting the valve stem pin 

3.9.

 

Press any button to initiate the Adaptation process  

3.10.

 

The TRV will remain in the Joining mode for 10 minutes 

4.

 

From the App 

4.1.

 

Wait for devices to be found, click on the devices to: 

4.2.

 

Give the devices a meaningful name 

4.3.

 

From the dashboard, select the Thermostat you want to Pair the TRV with, 
by clicking on the tile 

4.4.

 

Click on the Thermostat name 

4.5.

 

To edit, click the 

 on 

 

4.6.

 

Select the TRV - click box to turn Green, click Save 

 

4.7.

 

The TRV has now Joined the network and Paired with the Thermostat and 
the LED will turn OFF 

 
Note:  If the TRV does not complete the Pairing process and no button is pressed 

 

After 10 minutes the TRV will automatically retract the pin (LED rapidly 
flashing 

Red

) so the TRV may be mounted on the valve.  During this 

time, the TRV cannot Join/Pair 

 

After 20 minutes, the TRV will initiate the Adaptation process. During 
this time, the TRV cannot Join  

 

Press the RADIO button for 10+ seconds to initiate the 

Joining

 mode 

INSTALLATION 

1.

 

Remove the existing head. 

2.

 

Confirm the TRV pin is retracted (see 3.7 
above)

 

 

3.

 

Thread the TRV onto the radiator valve. 

NOTE:  Rotate the TRV so that the 

battery door is accessible 

4.

 

Tighten the mounting ring finger-tight 
to the valve 

NOTE: Do not use tools or over tighten 

5.

 

Press any button to initiate the Adaptation process which takes approximately 
4 minutes as the TRV calibrates itself to the valve 
5.1.

 

The TRV will go through a sequence of 
5.1.1.

 

Closing the valve (LED flashes 

Green

5.1.2.

 

Opening the valve (LED flashes 

Orange

5.1.3.

 

Closing the valve (no LED however if you listen closely, you will hear 
the valve motor running) 

5.2.

 

The TRV will position the valve based on the command from the AWRT 
5.2.1.

 

If the TRV has not Paired with the AWRT it will move to its Fail-Safe 
position of 25% open 

 

 

 

 
 
 
 
 
 

NOTE:  Once the TRV has completed the Adaptation process do not rotate the 

TRV counterclockwise as it may loosen the mounting ring 

ADDITIONAL FUNCTIONS 

Auto Lock function 

Once paired, the thermostat controls the TRV and after 5 minutes the TRV 
buttons are locked.  

 

To unlock – Press RADIO + CLOSE button for 3 seconds, LED flashes 

Green

 

once 

 

To lock – Press RADIO + CLOSE button for 3 seconds, LED flashes 

Red

 

once 

 

TRV will Auto Lock after 5 minutes if no buttons are pressed. 

 

 

 

LED 

Indicator 

CLOSE 

OPEN 

RADIO 