8.2 ARC calibration
Motors are adjusted before exit-factory. Certainly, these settings may change for a
variety of reasons. This function automatically calibrates the speed of 4 motors.
Operations
Choose [ARC calibration] in [system maintenance].
Prepare for the fiber and put into fusion splicer, press [set] to start .
Speed of all motors will be automatically calibrated, and will hint for
completion.
Atmosphere like temperature, humidity, air pressure are always changing. This
makes the discharging temperature change as well. The machine is equipped with
temperature and air pressure sensor which can give feedback to the control system to
adjust the discharge intensity to maintain a steady state. Automatic calibration is not
suitable for changes caused by the wear of motors and fiber trash adhesion, and the
center position of discharging sometimes moves to the left or right. In this condition,