To lubricate the GFA module:
1.
Use a grease gun to apply lubrication to every grease nipple of the GFA module.
The number of grease nipples varies with the design of the GFA module.
2.
Operate the system a few times.
3.
Remove any excess grease with a clean, smooth cloth.
Dismantling/Assembling Instructions
Removing a Quick Index Adapter
1.
Fasten the GFA system, together with the drive unit, in a vice.
2.
Loosen the drive unit from the adapter.
The adapter is left-hand threaded. Turn the drive unit clockwise for loosening.
The adapter is fixed to the drive unit with Loctite. Loosening the tool from the adapter requires
strong force. It is recommended to use a heat gun to facilitate the loosening.
3.
Remove the drive unit from the adapter.
4.
Loosen the ring inside the adapter. For service tool information, see the spare parts list of the specific
GFA model.
5.
Remove the ring and the adapter from the GFA unit.