Salto Ec DR Series User Manual Download Page 1

 

 

Desktop Reader Manual V2.1

 

  

26/02/2007 

 

  

1/11 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOCUMENT REVISIONS 

 

Version Date 

Modifications 

1.2 5/03/2004 

 

1.3 

11/03/2004 

Note on Wall Reader Adaptor about minimum wall 
reader versions. 

1.4 

12/03/2004 

Fixes mistake on Desktop Reader Connector. 

1.5 

25/03/2004 

Minimum WR2000 firmware version to read ROM 
code from iButtonROM. 

1.6 

11/08/2005 

NEW: ROM code configuration. 

BCD Data Format (ANSI/ISO): It is used in Track 2 
and Track 3. 

New Card Technologies (Mifare, Desfire…) 

2.1 

 

26/02/2007 

New Firmware Version 02.01 

New RS232 Plain Text Format. 

New Wiegand formats. 

 

 

Desktop Reader and Wall Reader Adaptor 

USER MANUAL 

Version: 2.1 

 

Distribution: SALTO customers 

Summary of Contents for Ec DR Series

Page 1: ...p Reader Connector 1 5 25 03 2004 Minimum WR2000 firmware version to read ROM code from iButtonROM 1 6 11 08 2005 NEW ROM code configuration BCD Data Format ANSI ISO It is used in Track 2 and Track 3...

Page 2: ...dip switches table 5 7 Data 6 7 1 ROM code 6 7 2 Tracks 7 7 3 Wiegand code 7 8 Interfaces 7 8 1 RS232 interface 7 8 2 OMRON interface 8 8 3 WIEGAND interface 8 9 Formats 8 9 1 RS232 format with STX E...

Page 3: ...tton except in Proximity readers when you need to enter a new SAM card The CLR button is only accessible opening the case of the Desktop Reader 2 2 Desktop Reader Connector The functions of the 9 pins...

Page 4: ...ins V and GND Optionally can be powered through the jack connector The Wall Reader Adaptor is continuously looking for a card and when one is presented it sends the data to the external device giving...

Page 5: ...two seconds except Legic SAM that lasts around 15 seconds 6 MODE dip switches table MODE Notes Data Interface Format 00000001 Track1 RS232 19200 8 N STX ETX LRC 00000010 Track2 RS232 19200 8 N STX ET...

Page 6: ...mmed code particular for each card TRACKS Emulates the Tracks 1 2 and 3 of the magnetic stripe cards WIEGAND CODE Emulates de Wiegand code of access control cards 7 1 ROM code The Salto ROM code is a...

Page 7: ...dentifier UID also called Serial Number SN of the Mifare card starting by the LSB Followed by three null bytes 0x00 Desfire The seven bytes of the card UID or Serial Number SN starting by the LSB ISO1...

Page 8: ...rs are common to various interfaces 9 1 RS232 format with STX ETX and Checksum The transmitted characters are all printable ASCII characters except 2 control characters that helps to determine where t...

Page 9: ...st Significant Bit First Parity bits The two parity bits are one Even parity bit of the first half bits at the beginning and one Odd parity bit of the last half bits at the end Data for Wiegand is usu...

Page 10: ...acters and ASCII values Printable characters ASCII value 1 byte BCD codes 4 bits parity ALPHA codes 6 bits parity Space 0x20 00 0x21 01 0x22 02 0x23 03 0x24 04 0x25 05 SS 0x26 06 0x27 07 0x28 08 0x29...

Page 11: ...des to Track1 some others do not use the standard Sentinels or Field Separators 11 5 LRC The LRC Longitudinal Redundancy Code is the exclusive OR XOR including the Start and End Sentinels SS and ES in...