LOOKING AFTER YOUR SALTMATE POWER PACK
Do not carry out any maintenance or repair work other than that shown in this
operating manual
or advised by Saltmate, and only use parts recommended by Saltmate. If you do not
it could
invalidate your warranty.
• Do not store pool chemicals in a confined space with your Saltmate. The fumes can breach
cooling vents and damage vital components.
• Small insects can also enter cooling vents causing damage to vital components. To avoid this
happening, routinely spray insect repellent to the surfaces around the power pack.
NO WATER FLOW
Saltmate cells contain a sensor that checks for proper water flow and for safety purposes if
adequate water flow is not sensed your Saltmate will cease to produce chlorine until the
problem is resolved.
If this situation occurs, the chlorine output indicator will drop to zero, while RP models also
have
a no flow indicator light which will light up if proper water flow is not detected and turn off once
the problem has been resolved.
SETTINGS FOR POOL OPERATIONS
The following is a guide to setting your Saltmate to perform various pool operations.
OPERATION
240V SUPPLY
CELL SWITCH
PUMP SWITCH
Run pump & chlorinator via timer
ON
ON
AUTO
Run pump & chlorinator manually
ON
ON
MAN
Vacuum or backwash
ON
OFF*
MAN
Clean cell or cartridge filter
OFF & REMOVE PLUG
OFF*
OFF
* When turning cell switch to the ‘off’ position for backwashing, cleaning cartridge or cleaning
cell REMEMBER
to turn cell back to the ‘on’ position when resuming normal filtration operation.
Similarly if you have turned any valves to the ‘closed’ position to clean the cell or the cartridge
filter remember to turn them back to the ‘open’ position before resuming water flow.
Operating Your Saltmate