The Power Pack
Your Saltmate is weather protected to an IP34 rating. The power pack should be mounted to the
bracket 1 to 1.5 metres above ground level and located so that the cell power lead can reach the
junction box.
Your Saltmate should be installed in a well ventilated position ensuring that pool chemicals (esp.
acid) are not stored in the direct vicinity, as the fumes may damage vital components.
Plug the 3-pin power plug of your Saltmate into a suitable 240 volt A.C power supply. Plug the
3-pin power plug of your filter pump into the 240 volt A.C power point on the underside of your
Saltmate power pack. Please ensure that only the one filter pump is plugged into the socket at
the base of the power pack.
The Electrolytic Cell
Your Saltmate cell must be plumbed last in the pool pipework after all other pool equipment just
before the return to the pool, ensuring the cell can be removed. For maximum efficiency your
cell should be installed with the water entering the cell housing at the end closest to the cell
lead (see image below).
Ensure that the cell is positioned horizontally so that the gas bubbles formed by the cell will be
trapped in the cell housing when the pump is turned off. If you are in any doubt about the gas
trap requirements
please contact Saltmate head office, or your Saltmate supplier.
The cell lead must be connected to the junction box under the power pack. Connect
blue to
blue, brown to brown and black to black. Be sure to replace the junction box cover.
Installation Instructions
ELECTROLYTIC SALT CELL (Size and type vary by model)