background image

11

Current setting, 

Zero0.5 

through

 Zero5.0

, is displayed.

4.

Press the 

F

 key repeatedly to scroll through the choices. Choices 

are in 1/2 division increments. When your choice is displayed, press 
the 

TARE

 key…

5.

The function is set and the scale returns to normal weighing mode.

bUZZEr

Use this item to set the Accept buzzer or beeper on or off. If you choose 
on, the unit will beep when a steady weight is in the Accept range. If you 
choose oFF, the beeper will not sound.

Set using the directions below.

1.

Press and hold the 

F

 key for three seconds to access the 

Configuration menu …

rAnGE

 is displayed.

2.

Press the 

F

 key five times…

bUZZEr

 is displayed.

3.

Press the 

TARE

 key…

Current setting, 

on 

or

 oFF

, is displayed.

4.

Press the 

F

 key to toggle between the choices. When your choice is 

displayed, press the 

TARE

 key…

5.

The function is set and the scale returns to normal weighing mode.

7.0

Calibration

You can calibrate this scale using single point or multpoint calibration. 
Single point calibration uses just the empty scale and a test weights equal 
to full capacity to calibrate the scale. During multipoint calibration, you can 
choose between a powerup zero range of 20% or 100% and use zero 
weight, 1/3 capacity, 2/3 capacity and full capacity test weights.

Single Point Calibraiton:

Follow these steps for single point calibration of the scale. You will need 
test weights equal to full capacity.

1.

Place the calibration switch, located on the bottom of the scale into 
the ON position. The ON position is when the switch is pulled 
towards the front of the scale. You may need to remove the small 
cover to access the calibration switch. Use a small screwdriver to 
remove the two screws holding the cover.

Summary of Contents for C3235

Page 1: ...ront panel of the unit The front panel includes the display window the annunciators arrayed around the display the four keys and the bubble level Figure 1 1 C3235 front panel NOTE This product is rate...

Page 2: ...ust recharge the battery soon CAEnd This is displayed when calibration is finished Err 0 A zero point error has occurred C_End This is displayed when the battery is fully recharged ZERO key Press this...

Page 3: ...e inactivity the scale goes into auto power saving mode and the display shows a small o To wake the scale up place a weight on the scale platform 4 If the battery voltage drops below 5 6V the scale wi...

Page 4: ...emove the item s and repeat steps 2 through 4 for the next item s 4 0 Tare weighing 1 Power up the scale 2 Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item to be ta...

Page 5: ...weight is displayed and the Over Accept or Under annunciator lights You must set the acceptable window parameters in the Configuration menu which is described in rAnGE on page 6 4 Remove item from the...

Page 6: ...h of these parameters is described below Accessing the Configuration Menu and Setting Parameters To access the Configuration menu press and hold the F key for three seconds rAnGE the first menu item i...

Page 7: ...eighed Remember as you set the values for the lower and upper ranges that the decimal does not appear on the display but you enter the values as if it were For example If you want 2 85 pounds as the h...

Page 8: ...through the choices Lb Lb This is the pounds unit of measure Lb oZ This is the pounds ounce unit of measure PcS This is the counting function HG This stands for KG or kilogram G This is the gram unit...

Page 9: ...o enter 25 you must press the TARE key three times to move the flashing digit to the right three times then enter 2 and 5 so the display looks like this 00025 After the last digit is entered the scale...

Page 10: ...s displayed This is the filter setting The noisier the environment the scale is in the higher the filter setting you should choose This means if the scale sits in a place that is subjected to vibratio...

Page 11: ...he choices When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode 7 0 Calibration You can calibrate this scale using single point or multp...

Page 12: ...hold the TARE key to enter calibration and repeat the calibration process Multipoint Calibration Follow these steps for multipoint calibration of the scale You will need test weights equal to 1 3 2 3...

Page 13: ...ter and press the TARE key when the display becomes stable The display shows c 0 with the c flashing At this point you can input a gravity adjustment 10 Press ZERO to increment the factor by one Press...

Page 14: ...15 30 Max Cap 3kg 6lb 6kg 12 lb 15kg 30lb Division Size 0 5g 0 01 lb 1g 0 02 lb 2g 0 05 lb Max Tare 100 Accuracy Class III Pan size 7 5 x 9 Working Temperature 23 95 F 5 35 C Power 6V4 5Ah rechargeab...

Page 15: ...15...

Page 16: ...ll Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com October 2014 C3235_u fm AWT35...

Reviews: