RIS 400-700 P EKO 3.0 v2019.06
21.6. RIS 700 PE 3.0 R EKO 3.0
Color markings:
WH(BK) - White(Black)
RD - Red
GN(BU) - Green (Blue)
YE - Yellow
STA
RT-
N
C
ST
O
P-
N
O
Jumper
Fire alarm
input
damper actuator damper actuator
Extract air
Supply air
L
L c
ont
rol
N
L c
ont
rol
ON/OFF
ON/OFF
230V AC
230V AC
15
20
16
L
L
N
N
L
18
17
M3
M2
X16.5
19
L
N
17
16
15
14
13
12
11
X16.6
22
21
temp.sensor
TJ
Supply air
NTC
11 12 13 14 15 16 17
X16
18 19 20 21 22
22
21
20
19
18
23
P
Transmitter 1
23 - 24V DC,
24 - intput, 0-10V DC,
25 - GND,
24 25
12
11
AHU
wo
rk
1.
2W
m
ax
X16.4 9 10
6
5
4
1.
2W
m
ax
AH
U s
to
p
X16.3
7 8
BO
O
ST
14
13
X16.2
X16.4
X16.4
DX Cooling
P
1
3
24V
D
C
24V
D
C
AHU stop
AHU work
AHU status
Start/Stop
Boost
1 2 3 4 5 6 7 8 9 10
10
9
8
7
6
5
4
3
2
1
Y1 - OPEN (24VAC)
Y2 - CLOSE (24VAC)
G - System potential 24VAC
24VAC, 3-position
M5
G
Y2
Y1
X16.1
2 3
1
Water cooler
valve actuator
23
25
24
26
28
27
23
25
24
26
28
27
26
P
27 28
X16.10
26 - 24V DC,
27 - intput, 0-10V DC,
28 - GND,
Transmitter 2
PV - supply air fan EC.
IV - extract air fan EC.
KE1 - supply air heater.
AT1 - automatic reset thermostat supply air heater.
RT1 - manual reset thermostat supply air heater.
TL - outside air temperature sensor.
TJ - supply air temperature sensor.
TE - exhaust air temperature sensor.
DTJ100 - extract air hu temperature sensor.
M1 - BYPASS damper actuator.
M2 - outside air damper actuator.
M3 - extract air damper actuator.
M5 - water cooler valve actuator.
FA - fire alarm input.
P/U - "Transsmiter 1" supply air fan pressure transmitter
(0-10 VDC).
P/U - "Transsmiter 2" extract air fan pressure, CO2
transmitters (0-10 VDC).
P - DX cooler protection, differential pressure switch.
KE1 - electrical heater 3,0kW/230V, 1f.
RG1 - PRV-V2.5.
RG2, RG3 - controllers ESKM1-26/176-30.
Q1 - disconnector.
Q2 - circuit breakers.
F1 - fuse (size 5x20)
Air quality transmitter
Supply air pressure
Air quality transmitter
CO2; Extract air pressure
FA
Jumper
A2
A1
A2
A1
7
2
1
X21
YE
G
N(
BU)
R
D
PW
M
ST
OP
- N
O
S
TA
R
T-
N
C
X33
.15
X3
3.
16
C
O
M
A.
0.
10
L
X
31
24V
D
C
24V
D
C
X
41.
1
X
41.
2
X
39.
2
X
39.
1
X3
8.
1
X3
8.
2
X4
0.
3
X4
0.
2
X4
0.
1
X3
4.
8
X3
4.
7
X3
4.
6
X3
4.
5
X3
4.
4
X3
4.
3
X3
4.
2
X3
4.
1
X33
.26
X33
.25
X33
.17
X33
.12
X33
.18
X33
.14
X33
.13
X3
5.
1
X3
5.
2
Y1 - Control OPEN (AC 24 V)
Y2 - Control CLOSE (AC 24 V)
G - System potential AC 24 V
24VDC
X16.1
2
1
3
X
33.
5
X
33.
4
X
33.
3
VAL
+
VAL
-
VAL
Y1 Y2
24VAC, 3-position
M5
G
11
14
C
O
M
B.
0.
10
2
Q2
1
DX Cooling
P
1
3
F1 5 A
1
2
L
N
X2
5
X
29
23
P
24 25
FAN
C
O
M
12
11
Fan
run
1.
2W
m
ax
+24
X16.4
9 10
6
5
4
1.
2W
m
ax
Fan
fal
l
A
N
TI
.F
C
O
M
X33
.11
ALA
R
M
X16.3
7 8
R1
A1
A2
BO
O
ST
X33
.10
C
O
M
X3
3.
9
C
H
IL
X3
3.
2
M
ID
L
X33
.15
C
O
M
X3
2.
3
TI
M
E
X3
2.
2
H
IG
H
X3
2.
4
C
O
M
X3
2.
1
LO
W
46
53
Q1
L1
PE N
TL
X37
L
ON/OFF
ON/OFF
230V AC
230V AC
L s
upp
ly
20
L
L
N
N
L
18
17
19
M3
M2
X16.5
X16.6
21
22
14
13
TA
RG1
Remote control
RS485_1
TJ
C
O
M
T.
O
U
T
R
S485
_1
N
L
X8
C
O
M
L (
cl
ose
)
N
X
33.
13
X10
EXT
-
EXT
+
AC
.N
L (
op
en
)
L c
ont
ro
l
EX
T+
EX
T-
EX
T-
EX
T+
N
N
N
L c
ont
ro
l
L s
upp
ly
N
X
35.
5
X
35.
4
X
35.
3
X
33.
21
X
33.
22
TJ
T.
W
AT
C
O
M
X
33.
20
X
33.
19
X52
TE
TE
A3
A3
A2
A2
A1
A1
R
S485
_2
RS485_2
ModBus RTU
X3
X4
X3
7.
4
X
37.
3
V2
C
O
M
X37.
1
X
37.
2
X4
2
X1
5
C
O
M
V1
1
N
L
X3
2 3 4 5 6 7
AC
.N
PU
M
P
A4
A4
H
R
X16.2
15 16
...9
PE
PE
23 - 24V DC,
24 - intput, 0-10V DC,
25 - GND,
X33
.22
X33
.21
C
O
M
T.
se
t
28
27
P
26
X16.10
X22.2
8
9
10
11
12
X
22
.3
Lo
ut
Li
n
2
1
RG2
TK
TK
0
W
H(
BK)
A1
A2
KE1
3x1000W/230V
X22.1
6
5
4
3
2
1
K1
4 6
2
5
3
1
13
14
K1
A2
A1
X01
X02
2
1
C
RT1
A2
A1
K1
AT1
1
2
C
EK
Transmitter 2 (24 VDC)
26 - 24V DC,
27 - intput, 0-10V DC,
28 - GND,
Transmitter 1 (24 VDC)
B16
24VDC
2
3-position
1
3
M1
1 - GND
2 - 24V open
3 - 24V close
BK
WH
RD
1
2
3
Jumper
X23
PE
N
X32
X33
+
PE
N
L
PV
GND
0-10V
in
8
7
6
5
4
3
2
2
3
4
5
6
7
8
0-10V
in
GND
IV
L
N
PE
+
1
1
D
M
P
X
33.
8
D
M
P+
X
33.
6
D
M
P-
X
33.
7
1.736.0007A.0.1.0-L-2k
+5V
TA
CO
M
RH
RH
U
TA
R
D
W
H
YE GY
Jumper
FA