23. DECLARATION OF CONFIMITY

Manufacturer

SALDA, UAB

Ragainės g. 100

LT-78109 Šiauliai, Lithuania

Tel.: +370 41 540415

www.salda.lt

Hereby confirms that the following products - Air handling units:

RIRS V EKO 3.0*

(where by “*” indicates possible unit installation type and modification)

Provided it was delivered and installed in the facility in accordance with the included installation instructions, comply

with all applicable requirements in the following directives:

Machinery Directive 2006/42/EC

EMC Directive 2014/30/EU

Ecodesign Directive 2009/125/EC

The following harmonized standards are applied in applicable parts:

LST EN ISO 12100:2011 - Safety of machinery - General principles for design - Risk assessment and risk reduction.

LST EN 60204-1:2006 - Safety of machinery - Electrical equipment of machines - Part 1: General requirements.

LST EN 60335-1:2012 - Household and similar electrical appliances. Safety. Part 1: General requirements.

LST EN 60529:1999 - Degrees of protection provided by enclosures (IP code).

LST EN 61000-6-2:2005 - Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments.

LST EN 61000-6-3:2007 - Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and 

light-industrial environments. 

Should any alterations be made in the products, this declaration will no longer apply.

Notified body: 

VšĮ Technikos priežiūros tarnyba, Naugarduko g. 41, LT – 03227 Vilnius, Lithuania, identification number 1399.

Quality:

  Salda UAB activities are in line with the international quality management system standard 

ISO 9001:2015. 

Date                          2019-02-01

Giedrius Taujenis

Director product development

Summary of Contents for RIRS 400 V EKO 3.0 Series

Page 1: ...RIRS 400 700 V EKO 3 0 EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...R 9 17 2 POSSIBLE FAULTS AND TROUBLESHOOTING 9 18 MAINTENANCE 9 18 1 FILTERS 9 18 2 FAN 10 18 3 HEAT EXCHANGER 10 18 4 ELECTRICAL HEATER 10 19 AUTOMATIC CONTROL 11 19 1 SYSTEM PROTECTION 12 19 2 USING...

Page 3: ...uency Max current Max power consumption Protection class Weight xxx xx VAC Hz x xx A x xx kW IP xx xx kg Made in iauliai Lithuania AHU000000 BN xxxxxx 2019 01 01 SERIAL 2514523357 XXX GAMINIO PAVADINI...

Page 4: ...make sure that it is not stuck or blocked check the grounding make sure that all components and accessories are connected in accordance with the project or provided instructions Danger Fumes Salda An...

Page 5: ...phase voltage 50 Hz VAC 1 1 AVS 250 AVS 250 power consumption kW 2 0 2 0 Fans phase voltage 50 Hz VAC 1 1 1 1 exhaust power current kW A 0 222 1 8 0 222 1 8 0 217 1 88 0 217 1 88 speed min 1 3380 3380...

Page 6: ...15 C o 40 C o 5 C o 40 C o 15 C 10 o o C 40 C o 15 C o 40 C o 3 C o 40 C o 8 PACKAGE H L W RIRS V EKO 3 0 H W L QUANTITY ON THE PALLET mm mm mm units 400 1055 785 1270 1 700 1210 795 1240 1 9 TRANSPOR...

Page 7: ...re delivered before starting the installation Any deviation from the ordered equipment must be reported to the supplier of products 11 STANDART PACKAGE OF COMPONENTS RIRS EKO 3 0 400 VER 400 VEL 400 V...

Page 8: ...re sensor IV Exhaust fan TE Exhaust air temperature sensor KE1 Electric heater DTJ Extract air temperature and RH sensor PE1 Electric pre heater T2 Cooler changeover thermostat KV2 Water pre heater TV...

Page 9: ...nts as well as automation and automation devices were not damaged during installation all electrical devices are connected to power supply and fit for service all necessary automation elements are ins...

Page 10: ...d from power source before performing any maintenance or repair Proceed to maintenance and repair after any rotation in the fan stopped Clean it once a year The maintenance works for the rotor heat ex...

Page 11: ...ped using the START STOP feature STOP is displayed at the remote control panel FLEX In START mode the recuperator operates based on the latest settings of the panel FanFail and FanRun features It prov...

Page 12: ...e cover of the heater When manual thermal protection is triggered fans operate in maximum capacity until the manual heater protection is reset by pressing the reset button and the device is restarted...

Page 13: ...ead_Coils 10 1 Return water temperature sensor alarm 1 a c t i v e o passive 11 ToutDoor 01h_Read_Coils 11 1 Outside air temperature sensor alarm controller continues to work in determining ToutDoor 0...

Page 14: ...ct air damper actuator damper actuator Fire alarm input Air quality transmitter Air quality transmitter Fire alarm input damper actuator damper actuator Extract air Supply air L L control N L control...

Page 15: ...necessary to properly install antifreeze protection from possible freezing of heat carrier Antifreeze temperature sensor TV must be mounted in clamp on return pipe of the water heater Capillary senso...

Page 16: ...9 06 20 1 LABELING CHARACTERISTICS OF THE CONTROLLER AND THE SYSTEM COMPONENTS Contact No Labeling Description I O type Max load Min load A mA X10 L 230V 50Hz power supply I X8 N 230V 50Hz power suppl...

Page 17: ...O X33 5 VAL Cooling valve common Pulse 24v 50hz AO M1 By pass actuator X33 6 DMP Bypass damper opening PWM 24v 50hz AO 100mA X33 7 DMP By Pass damper closing PWM 24v 50hz AO 100mA X33 8 DMP By Pass da...

Page 18: ...2 COM PV Supply air fan X37 1 V1 Supply air fan 0 10V AO X37 2 COM COM IV Extract room s air fan X37 3 V2 Extract air fan 0 10V AO X37 4 COM COM 20 2 REGULAR SYSTEM CHECK UP The operation of the swit...

Page 19: ...16 3 7 8 R1 A1 A2 START NC STOP NO BOOST X33 10 COM X33 9 CHIL X33 2 MIDL X33 1 COM X32 3 TIMER X32 2 HIGH X32 4 COM X32 1 LOW TL X37 L ON OFF ON OFF 230V AC 230V AC L supply 20 L L N N L 18 17 19 M3...

Page 20: ...25 26 27 X38 1 X38 2 X40 3 X40 2 X40 1 TA HR 24V DC C S1 COM 1 X21 2 3 9 8 W3 W2 W1 7 BN BU BK 6 5 N X24 4 3 2 C L N PE R 1 X40 L X31 X33 15 X33 16 COM A 0 10 24VDC 24VDC X41 1 X41 2 X39 2 X39 1 X34...

Page 21: ...EN 21 RIRS 400 700 V EKO 3 0 v2019 06 21 3 RIRS 700 VE EKO 3 0...

Page 22: ...26 27 28 X38 1 X38 2 X40 3 X40 2 X40 1 TA HR 24V DC C S1 COM 1 X21 2 3 9 8 W3 W2 W1 7 BN BU BK 6 5 N X24 4 3 2 C L N PE R 1 X40 L X31 X33 15 X33 16 COM A 0 10 24VDC 24VDC X41 1 X41 2 X39 2 X39 1 X34...

Page 23: ...erage kWh a 4224 4224 4224 4224 AHS Cold kWh a 8262 8262 8262 8262 AHS Warm kWh a 1910 1910 1910 1910 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www salda lt RIRS...

Page 24: ...24 EN RIRS 400 700 V EKO 3 0 v2019 06 AHS Warm kWh a 1885 1885 1885 1885 ErP Compliance 2018 2018 2018 2018 Internet address for disassembly instructions www salda lt...

Page 25: ...k reduction LST EN 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General r...

Page 26: ...ver the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic error...

Page 27: ...27 RIRS 400 700 V EKO 3 0 v2019 06...

Page 28: ...NANCE TABLE Product name LOT number Instalation Interval Datum Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE...

Reviews: