background image

Model No.

Input

(V)/(Hz)

Power

(W)

Lumens

(lm)

In-rush Current

(A)

Line

Current (A)

CCT (K)

CRI

Mass

(N.W. kg)

 

Dimension

L x W x H (mm)

SPK1000 DL BK

STARLIGHT SPK1000, SPSK1000, SPK2000, SPSK2000 LED FLOODLIGHT electrical and installation specification effective 29/10/2019. 

240/50

12

6000

SPSK1000 DL BK

240/50

12

6000

Beam

Angle

100°
100°

2 x 100°
2 x 100°

SPK2000 DL BK

240/50

2 x 12

6000

SPSK2000 DL BK

240/50

2 x 12

6000

> 80
> 80
> 80

> 80

Electrical class

Fitting colour

Power Factor

Earth Leakage current

Operating ambient min/max (°C)

Storage ambient limit (°C) 

Operating humidity

Storage humidity 

Calculated TM - 21, L

70 

@ 85 °C (hrs)

70 

@ 85 °C (hrs)

Reported TM - 21,L 

Aiming restrictions (if any)

Product application
Product installation orientation

CCT (k) switch control (TC)

Dimmable

Insulation cover rating (if any)

PIXIE connectivity

No (see clause 8) 

Replaceable LED

No (see clause 8) 

IP rating
Attachment type

User replaceable LED
IP rating for interior products: The designated IP rating is “from below the ceiling” unless otherwise specified.
IP rating ALL products; Termination of the product must be made in accordance with the IP rating.
Earth Leakage current: Is calculated in accordance with AS/NZ 60598.1.2013 table 10.3.

Yes, (Non-sensor models)

N/A

 

IP54

10% to 70% RH, NC
60,000

< 1mA
-20 to 60
10% to 70% RH, NC
> 54,000

Class II

No

Black

No

-10 to 40

> 0.9

N/A

N/A

Residential and Commercial exterior spaces
Vertical wall mount

0.2A MAX.@100μs

0.15
0.15

2 x 0.15
2 x 0.15

0.2A MAX.@100μs
0.2A MAX.@100μs

0.2A MAX.@100μs

0.61
0.73
1.02

214 x 216 x 214
214 x 126 x 214
214 x 310 x 214
214 x 310 x 214

1.18

1050
1050

2 x 1050
2 x 1050

General product application requirements (where applicable) :

2. Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.

3. Switching or test intervals  For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision of 
a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications and six 
(6) hour duration for Residential applications should be considered. 

1. CCT or POWER selection (where supplied) – IMPORTANT, where CCT or POWER selection switching is provided, it is important to switch OFF the SUPPLY before the CCT 
selection is made, otherwise equipment damage may occur. 

6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party
changes in dimmer compatibility.

7. Suspended products – For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.

5. Adverse, corrosive and coastal installation applications  Unless the product is specifically designated for such applications in these installation instructions, which is
supported by a professional maintenance program; installation of equipment in such environments is not recommended.

4. Product maintenance  In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that 
reflects the installation environment and maintains the product in a clean and functional condition.

IMPORTANT - The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the 
product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an 
equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be 
exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable 
cannot be replaced and the luminaire must be destroyed.

For sensors in SPSK1000 DL BK and SPSK2000 DL BK:

Power (W)

Input

(V)/(Hz)

 

Working

Humidity (RH)

Detection

Angle

Detection

Motion Speed (m/s)

Detection

Distance (m)

Time

Setting

Light

Control (lux)

 

Installation

Height (m)

Sensor 

Type

0.45 ( Idle 0.1W)

240/50

12m @ 2.5m height

0.6~1.5

< 93%

180°

10sec ~ 4min

< 10~2000

1.5 ~3.5

PIR

 

 

IK rating (if relevant)

N/A

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.

SAL products are designed in accordance with all mandatory International and Australian Standards, which require installation 

following instructions and SAL standard terms and conditions of sale, which are available via www.sal.net.au.

by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the  

MUST BE INSTALLED

BY A LICENSED

ELECTRICIAN

DIY

Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance 

guarantee unless expressly confirmed in writing by SAL at the time of order.

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474 

Copyright SAL V6 JUL19  |  

www.sal.net.au

  |  Page 1 of 2