background image

 

PD20Series

 

 
 

 
 

- 37 -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1.1 

Inverter

 

Summary of Contents for PDS23 Plus

Page 1: ...PDS23 Plus Solar Pump ControllerUser Manual Version code PDS23 Plus EN 60200183 1707...

Page 2: ...ler This manual provides you with relevant operation instructions and detailed description of parameters Please read this manual carefully before installation running maintenance or inspection Please...

Page 3: ...roller Model Description 11 2 5 Outline Installation Dimensions 13 Chapter 3 Mechanical and Electrical Installation 14 3 1 Mechanical Installation 14 3 2 Electrical Installation 15 Chapter 4 Start up...

Page 4: ...PDS23 Plus Series 3 5 2 Common Faults and Remedies 31 Chapter 6 Regular maintenance 33 6 1 Controller and Pump 33 6 2 Solar panels 33 6 3 Cable 33 Chapter 7 Backup AC power 34...

Page 5: ...ler is mountedin a protectivecabinet the cabinet need to setventstoensureambient temperature is below40 otherwise itmay be damaged because of high temperature When install the controller you should av...

Page 6: ...is installed in the well when the water level is below the level of water shortage the water pump will stop If there is no water level probe it will need to be short If a water level probe is not use...

Page 7: ...re those natural or special such as river lake well or waterway etc A float switch can be installed in the water tower to control the pump operation And install a low level probe in well to detect the...

Page 8: ...30m 100 ft of vertical pipe after the pump 1 1 Features System Diagnostics PDS23Plus solar pump controller continuously monitors system performance and detects a variety of abnormal conditions In man...

Page 9: ...ly Level switchforthe controlleris optional not mandatory Switching to Backup AC Power The input power of the PDS23 Plus solar pump controller can be switched to standby AC power through a power switc...

Page 10: ...s designed with the high standard of reliability expected of products The controller attempts to drive the pump and motor to deliver water even under adverse conditions reducing output as necessary to...

Page 11: ...easy to use interface is provided to enhance configurability and enable remote system monitoring A LED display provides a detailed indication of system status A small keypad offers flexibility for sel...

Page 12: ...cted to terminal R S and T 2 4 2General parameters of PDS23 Solar Pump Controller General Parameters Protection Surge Protection Integrated Overvoltage Protection Integrated Undervoltage Protection In...

Page 13: ...kW 2 7 3 5 4 8 6 4 6 6 8 8 9 12 13 2 17 6 Alternate AC Generator Input Voltage 380 400 415 440VAC 15 Three Phase Power and VA Capability kVA 4 0 5 9 8 9 11 0 17 Output Data Output Power Rated kW 2 2...

Page 14: ...dimensions diagram Unit mm 155 6 179 240 191 3 168 150 50 50 144 3 22 Figure 2 PDS23 Plus 2 2K PDS23 Plus 4K Outline installation dimensions diagram Figure 3PDS23 Plus 5 5K PDS23 Plus 7 5K PDS23 Plus...

Page 15: ...can prevent the equipment from overheating and performance degradation In extremely high temperature high temperature may cause the controller stop to protect itself 3 1 2 Location Selection The PDS2...

Page 16: ...system a two pole DC disconnect switch must be installed between the solar array and the PDS23Plus solar pump controller Connect the cables which comes from the two pole DC disconnect Switch downstre...

Page 17: ...lightning protection device and DC switch The fuse and the DC switch can prevent the short circuit protection the lightning protection device can play the direct current side the lightning protection...

Page 18: ...robe for the detection of the water level please keep the two terminals of the controller short The controller can also detect water through the built in software water detection function look upFD fu...

Page 19: ...the float switch is not required to be grounded If the float switch is not used the M6 and COM are kept short Figure 8 Float ball wiring diagram 3 2 8Electrical conduit When the system installed in t...

Page 20: ...he open circuit voltage is 37V Description of the number of input components in series The PDS23Plus series controller is connected in series with the serial number of the input components of the 18 2...

Page 21: ...n Description PRGM Program Exit Key Enter or exit of menu parameter modification ENT Data Enter Key Progressively enter menu and confirm parameter Up Increase Key Progressively increase data or functi...

Page 22: ...Function code second class Setting parameter of function code third class In order to set up the electric automatic start function FD 07 11 as an example the modified parameter flow chart is as follow...

Page 23: ...test the insulation of motor cable etc Use a multimeter to test the PV output voltage at the DC switch Power on the controller by switch the DC switch If necessary modify and set the parameters of mot...

Page 24: ...every120s and during the trial run the running indicator is always on When a shadow suddenly passes through the battery array the controller will lose track of the input voltage and the pump will stop...

Page 25: ...ing 1 Restore to factory setting 2 Fault record clearing 0 F2 Group Motor Parameters F2 01 Motor rated power 0 4 400 0 kW Different according to inverter model F2 02 Motor rated frequency 10 00 F0 10...

Page 26: ...tant speed E004 5 Over voltage when accelerate E005 6 Over voltage when decelerate E006 7 Over voltage at constant speed E007 8 Hardware overvoltage E008 9 Under voltage E009 10 Inverter overload E010...

Page 27: ...0 FD 13 Interval of water shortage detection 1 9000 min 20 Parameter interpretation F0 14 Low limit of running frequency this parameter defaults to 20Hz when the light becomes weak and the controller...

Page 28: ...nction of water shortage Software shortage detection principle If the water shortage happens the controller will still run FD 10 time after that it will appear the water shortage fault E026 The fault...

Page 29: ...controller has stopped to indicate a fault code on the display the associated time out delay will vary depending on the nature of the fault The number following the E symbol corresponds to the error...

Page 30: ...ous trip off occurs Avoid prompt restart when trip off E006 Over voltage during deceleration Too fast deceleration Add proper braking units Abnormal input voltage Check input power supply or wiring E0...

Page 31: ...ped or damaged Obstruction of ventilation channel Replace cooling fan and clear the ventilation channel Too high ambient temperature Decrease the ambient temperature if possible Loose cables or termin...

Page 32: ...etting of FD 12 Water shortage detection current ratio is too high while FD 10 Water shortage detection time is non zero and the current sensing is enabled Reduce setting value of FD 12 5 2 Common Fau...

Page 33: ...rotection Need to pull out the pump and check Because of the increase in operating current of the pump which is caused by the pump wire is too long the controller will be protected and the controller...

Page 34: ...is a mechanical device may be used for a period of time due to the sand in the water and other impurities cause a certain wear the performance of the pump needs to be regularly detected If the flow of...

Page 35: ...orm Warning at any time only one power supply can be entered otherwise it may cause the controller to damage Take three phase 380VAC backup AC power supply for example the wiring is shown in the follo...

Page 36: ...e ofPurchase Distributor Contact details System Controller Serial Number Motor Serial Numberor Power Pump Type Submersible Surface Solar Power Solar Module Manufacturers Type PeakVoltage V mp Open Cir...

Page 37: ...ft Static Water Level m ft Dynamic Water Level m ft Vertical Pipe in Well pump Suction Pipe Diameter mm inch Diameter mm inch Type Type Length m ft Length m ft Additional Pipe to water tower Vertical...

Page 38: ...PD20Series 37 V1 1 Inverter...

Reviews: