background image

 

 

 

2/7 

 

Thank you for selecting a SAINT-GOBAIN PERFORMANCE PLASTICS model MDP 50 pump. 
 
 

I – General 

 

I.1 – Introduction 

 
The model MDP 50 is a pneumatically operated PFA/PTFE dosing pump. 
 
The pump is designed for dosing of chemicals.  
 
 

I.2 – Materials 

 

All wetted parts are manufactured from PFA  and PTFE. 
 
 

I.3 – Operation description 

 
In this pneumatically operated dosing pump, there is a PTFE rolling diaphragm connected to a piston 
by a shaft. During the suction cycle, air/nitrogen enters the piston. On discharge cycle air/pressure is 
released and a spring pushes forward the piston. 
 
The pump is self-priming and has check valves. 
 
The pump stroke volume is adjusted manually with a fine adjustable stem at the top of the pump. 
 
The pump speed varies with operating conditions ( air pressure, viscosity, density….)  
 

 

I.4 – Pump data 

 
The main characteristics of the MPD 50 pump are: 

 

Repeatability 

+/- 1% 

 

Dispense volume per shot 

0 to 0,5 mL 

 

Dispense speed 

 0 to 0,5 mL/s max 

 

Delivery pressure 

4.3 psig (0.3 bar) max at 70 psig (4.8 bar) air actuation 

 

Air/nitrogen pressure 

50-70 psig (3,4-4,8 bar)

 

 

Suction height  

2 feet (0,6m)  based on water 

 

Product viscosity 

50 cPo max 

 

Liquid temperature  

41°F to 180°F (5°C  to 82°C) 

 

Ambient temperature  

32°F to 120°F (0°C to 50°C) 

 

Fluid connection  

1/4" Flare Grip II®   

 

Pump air connection  

1/8” BSPT 

 

Weight of the pump  

435g

 

 
 
 

II – Quick Checklist 

 

II.1 – Shipment 

 
 
Pump is cleaned, sealed in plastic bag, and packed in an individual carton. 
 

II.2 – Reception 

 
On receipt of the pump, check: 

 

The carton has not been damaged in transit. If there are signs of damage, you should report this 
immediately to the carrier.  

Summary of Contents for MDP 50

Page 1: ...INPERFORMANCE SAINT GOBAINPERFORMANCEPLASTICS PLASTICS FRANCE EADAC DES BERTHILLIERS 7301 Orangewood Avenue F 71850 CHARNAY LES MACON Garden Grove CA 92841 Tel 33 0 3 85 20 27 00 Tel 1 714 630 5818 Fax 33 0 3 85 29 18 48 Fax 1 714 688 2614 www microelectronics saint gobain com ...

Page 2: ...III 1 Testing III 2 Set up III 3 Connections III 3 1 Air nitrogen connections III 3 2 Fluid connections III 4 Initial tests and adjustments IV Applications 3 IV 1 Chemical compatibility IV 2 Temperature range IV 3 Cleaning IV 4 Single stroke adjustment IV 5 Limitations of use V Trouble shooting 5 VI Warranty safety 5 Appendix 7 Section view Dimensions Pneumatic wiring diagram ...

Page 3: ...he top of the pump The pump speed varies with operating conditions air pressure viscosity density I 4 Pump data The main characteristics of the MPD 50 pump are Repeatability 1 Dispense volume per shot 0 to 0 5 mL Dispense speed 0 to 0 5 mL s max Delivery pressure 4 3 psig 0 3 bar max at 70 psig 4 8 bar air actuation Air nitrogen pressure 50 70 psig 3 4 4 8 bar Suction height 2 feet 0 6m based on w...

Page 4: ...l valve is to control the speed of the suction cycle The integrated check valve is for a quick release of the pressure during the discharge cycle 3 2 way valve is necessary for the on off cycle of the pump When the 3 2 valve is actuated it is the suction cycle When the 3 2 valve is not actuated it is the discharge cycle Pressure regulator is to setup the right pressure Filter If the air nitrogen o...

Page 5: ...ge line It is recommended to adjust the stem to the maximum stroke 3 Check the delivered volume of liquid with a calibrated beaker test tube or a precision balance to calculate the single stroke 4 If unit stroke is not as required screw on the adjustable stem to reduce the stroke or unscrew it to increase the volume 5 Repeat the stroke until you get the required volume of liquid per shot 6 When th...

Page 6: ...e year from delivery date SGPPL is not responsible for damage to its products through improper installation maintenance use or attempts to operate them beyond their mechanical capability intentionally or otherwise or for unauthorized repair SGPPL shall not be liable for any indirect special incidental or consequential damages resulting from the use failure or malfunction of any product Safety hint...

Page 7: ...ted When the pump is handling liquids higher than 122 F 50 C avoid direct contact with the pump or piping system Use appropriate hand protection if handling of the pump or piping is necessary Always wear protective gear goggles face shield acid resistant gloves etc when removing or servicing the pump In addition flush the pump completely with di water prior to any service or maintenance Ensure suc...

Page 8: ...7 7 ...

Reviews: