51
Installation
Cable connection diagram
X7
SPARC II BUS
CONNECTIONS
CONNECTIONS
OPTIONS
39734B
X1
X2
X3
X4
X5
X6
VDR-
1
SPARC II
9
OPTIONS
AUX1
6
EXT LS2
8
CALL
GND
AUX2
+12.5V
INTERFACE
OPTIONS
LAN
NMEA+
EXT
10
NMEA-
2
Line out-
Line out+
RX AF+
3
4
7
15
14
13
12
11
TX AF-
RX AF-
EXT LS1
AUX1
VDR+
DATA-
TX AF+
EXT LS2
+12.5V
5
GND
GND
ALARM
CALL
DATA+
ALARM
AUX2
EXT LS1
+12.5V
5
11
12
13
14
15
7
4
3
2
10
8
6
9
1
H1
H2
H3
H4
X1
X3
X2
X4
X5
X6
J
2
J
1
7
4
2
5
LS-
3
6
DATA-
1
11
LS+
X1
+12.5V
8
12
13
15
GND
14
EXT LS+
11
7
3
10
6
Line out
1
5
2
4
X5
X6
X4
9
8
Line out
9
EXT LS-
CU LS+
+12.5V
GND
EB/CU
CB/RT50XX
CU
+12.5V
DATA+
CU LS-
X6 :
X3
X2
10
12
13
15
14
EB/CU
EXT /
CU LS
EB/CU
RT50XX
RT50XX
EXT /
CU LS
EXT/CU
LS-
EXT/CU
LS+
IF CU IS CONNECTED TO
EB/CU TERMINALS THEN
REMOVE
J
1
&
J
2 FOR X4
AND
J
3
&
J
4 FOR X5
J
1
&
J
2 MOUNTED = EXT LS
J
1
&
J
2 NOT MOUNTED = CU LS
To VHF DSC
cable part no. 56.114
To VHF DSC
To VDR
To ships alarm panel or announcer
From position sensor (GPS)
(mixed Rx/Tx Audio)
NMEA
To LAN interface (optional)
To Alarm Panel - (if installed)
To extension box for CU2
CU 1 (Optional)
Ext. speaker (CU)
Ext. speaker (VHF)
Cable part no. 539603
Cable part no. 56.111
0605