Installation of the SAILOR 6390 Navtex Receiver
98-139768-A
Chapter 3: Installation
3-5
3333
Installation
3. Connect the SAILOR 6004 Control Panel via LAN to the SAILOR 6390 Navtex Receiver or
connect NMEA OUT (to INS) and NMEA IN (from INS).
4. Use the integrated cable relief to secure the cables with the provided cable ties.
5. Fasten the lid on the SAILOR 6390 Navtex Receiver with 4 screws (included in the
delivery).
Navtex printer interface
The optional Navtex printer interface requires a printer attached to a LAN network. Two
setups are supported:
1. Using a Control Panel as LPR print server (requires attaching a USB printer)
2. Using a third party LPR print server (requires IP address, port and queue name of that
server)
3.2.5
Ethernet interfaces
The SAILOR 6390 Navtex Receiver has two Ethernet connectors (RJ45). The Ethernet
connectors are identical, you can use any of the connectors to connect the SAILOR 6390
Navtex Receiver to the SAILOR 6004 Control Panel.
The Ethernet interface is also used for communication with the Service Interface (opens in
a web browser). For more information see
Configuration with the Service Interface
LAN connector and cable
The SAILOR 6390 Navtex Receiver has two identical LAN connectors. Use one for
connecting the SAILOR 6004 Control Panel. The two connectors are of the type RJ45 with 8
leads
Figure 3-4: Spring-loaded terminals of the SAILOR 6390 Navtex Receiver (zoom)
LABEL
LABEL
J12
J11
J10
J9
C74
C73
C64
C63
R1112
R1111
R1110
J2
GND
FUSE
NMEA GPS
ALARM OUT
NMEA IN-
NMEA IN+
NMEA OUT-
NMEA OUT+
ON_OUT
/ON_IN
VBAT-
VBAT+
NMEA 2 IN-
NMEA 2 IN+
RX AUDIO
GND
ALARM OUT
Important
For GMDSS installations:
Only connect units that are part of the GMDSS
LAN system. For safety and compliance reasons, the Ethernet interface is
restricted to internal communication in an isolated system.