2-2
Metal Detector
METARIDDER
2.1
Running & Stopping
2.1.1
Running
1. Turn ON the Main circuit breaker.
(See Table 2, No. 15 in Section 1.2.1 Names and Functions of Various Sections of the
Machine.)
2. Press the Operation Switch on the left side of the door.
(See Table 2, No. 8 in Section 1.2.1 Names and Functions of Various Sections of the
Machine.)
3. The Operation Switch lights up in green.
* If the light tower is included in the option, the green indicator lights up.
Important
This machine is stabilized in approx. 60 seconds after the start-up. Supply the
material after elapse of at least 60 seconds.
When the sensor normally detects a metal piece (foreign object), the machine executes the
following operations:
The discharge damper starts its discharging operation.
When a detection is made, the yellow light on the light tower turns ON. (Only for the
machine with this option.)
The detection count value is incremented. (Only for the machine with this option.)
STOP
Running
During stabilization
(approx. 60 sec)
* Metal detection not
possible
Turn ON the circuit breaker
Light tower (optional)
OFF
Green light blinks
Green light ON
Machine state
Press the
Operation
Switch