![Sagetech MXS Installation Manual Download Page 25](http://html1.mh-extra.com/html/sagetech/mxs/mxs_installation-manual_3419262025.webp)
MXS System Description and Installation Manual
UM06945
© Sagetech Avionics 2022 Proprietary Confidential
Page 25 of 56
•
(a) device on insulated closed-cell foam pad, natural convection only on top and side surfaces.
•
(b) device on insulated closed-cell foam pad, ducted forced air cooling at 20.1 LFM on top and
side surfaces.
The temperature protection limit at 110 °C applies to the average internal device temperature. The
average device temperature is representative of the majority of PCBA components within the device.
The SoC within the device typically operates at a temperature delta of ~10°C above the average device
temperature and triggers overtemperature protection at a correspondingly higher temperature of
120°C.
Figure 4-4 Cooling Methods vs. Device Temperature