The terminal blocks are shown viewed from the front with the chassis
assembly in its normal position on the wall.
Terminal block J3
Pin 1 +12 V
Power
Pin 2 Ground
Power
Power supply 12 V ± 5% (regulated) 2.5 A
C
C
O
O
M
M
1
1
R
R
S
S
4
4
2
2
2
2
s
s
e
e
r
r
i
i
a
a
l
l
p
p
o
o
r
r
t
t
w
w
i
i
r
r
i
i
n
n
g
g
Terminal block J7
Pin 1
Rx+
Input
Pin 2
Rx-
Input
Pin 3
Tx+
Output
Pin 4
Tx-
Output
Pin 5
Ground
Ground
For a half-duplex RS422 connection, only Tx+, Tx- and ground are
connected. Otherwise, as the unit is a peripheral, the connections must be
crossed over: Rx on the MorphoAccess™ is connected to Tx on the host
and Tx on the MorphoAccess™ is connected to Rx on the host.