background image

 

 

 

D

D

a

a

t

t

a

a

c

c

l

l

o

o

c

c

k

k

 

 

l

l

e

e

v

v

e

e

l

l

s

s

 

 

In normal operation mode (default) input and output signals are defined 

as:

 

Other modes are (only for output): 

 

SK-0000011145-05 

SAGEM Défense Sécurité document. Reproduction and disclosure forbidden. 

111

 

Summary of Contents for MORPHOACCESS 200

Page 1: ...SAGEM D fense S curit MORPHOACCESS TM Installation Guide MorphoAccessTM 200 220 300 July 2006...

Page 2: ...2 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...

Page 3: ...7 ELECTRICAL INTERFACE 18 TERMINAL BLOCK BOARD 18 POWER SUPPLY CABLE 19 COM1 RS422 SERIAL PORT WIRING 19 COM1 DEISTER WIRING OPTIONAL 20 ETHERNET WIRING 20 COM2 RS232 WIRING 21 WIEGAND OUTPUT WIRING 2...

Page 4: ...R INTERFACE 48 BIOMETRIC MANAGEMENT OPERATIONS 49 BIOMETRIC MANAGEMENT BETWEEN TERMINAL AND MORPHOACCESS MANAGEMENT SYSTEM MMS 49 BIOMETRIC MANAGEMENT IN STAND ALONE MODE 50 INSERT TEMPLATE ID IN DATA...

Page 5: ...TTING UP TIME MASK 73 SETTING UP DOWNLOAD AGENT SDL 74 WIEGAND DATACLOCK CONFIGURATION 75 NOTE 75 WIEGAND DATACLOCK ID SENDING 75 WIEGAND DATACLOCK ADVANCED INFORMATIONS 76 WIEGAND FACILITY CODE 76 WI...

Page 6: ...URE MORPHOACCESS 220 ONLY 97 DATA STRUCTURE 97 MORPHOACCESS TAGS 97 ADMIN CARD FORMAT MORPHOACCESS 220 ONLY 99 SAGEM KEYS 99 MAPPING 100 COMMUNICATION PROTOCOL 101 MORPHOACCESS TECHNICAL CHARACTERISTI...

Page 7: ...DIX 2 WIEGAND DATA FORMAT 107 EXAMPLES 108 APPENDIX 3 ISO 7811 2 1995 TRACK 2 DATACLOCK FORMAT 109 DATA ENCODING TABLE 109 DATACLOCK LEVELS 111 APPENDIX 4 RESERVED CONFIGURATION 112 APPENDIX 5 FINGERP...

Page 8: ...8 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...

Page 9: ...llions of individual fingerprint identification records We believe you will find the SAGEM MorphoAccess fast accurate easy to use and suitable for physical access control or time and attendance The SA...

Page 10: ...he below listed standards as required by the EMC Directive 89 336 EEC EN55022 1994 EN55024 1998 and by the low voltage Directive 73 23 EEC amended by 93 68 EEC EN60950 2000 USA This equipment has been...

Page 11: ...eplace only with the same or equivalent type recommended by the manufacturer Must be disposed of properly ATTENTION ll y a danger d explosion s il y a remplacement incorrect de la batterie Remplacer u...

Page 12: ...TI IO ON N Sensor Display 136 x 34 dots MIFARE Card reader MA220 only Function keys Keyboard Mounting keyholes Cable entry Metal chassis Anti theft entry 12 SAGEM D fense S curit document Reproductio...

Page 13: ...5 05 SAGEM D fense S curit document Reproduction and disclosure forbidden 13 a Drill the 2 holes for the screws for the mounting keyholes so that the cable entry is in a suitable position for your cab...

Page 14: ...be detached from the rest of MorphoAccess b Pass the connecting cables through the cable entry c Position the chassis assembly against the wall using the two screws in the mounting keyholes d Hold the...

Page 15: ...or location Tamper switch SK 0000011145 05 SAGEM D fense S curit document Reproduction and disclosure forbidden 15 Motherboard terminal block board ribbon cable connectors Cover assembly Chassis assem...

Page 16: ...r assembly lip Lip When the ribbon cable has been connected between the two assemblies see stage 3 the cover assembly is fitted to the chassis assembly 1 The lip on the cover slides behind the chassis...

Page 17: ...on the 13 pin motherboard connector One pin of the motherboard connector must be visible on the left side of the external card flash while connected Bad positioning may damage the external card flash...

Page 18: ...et LAN J1 5 pin block Ethernet Interface LAN 10 Mbps J3 2 pin block 12 V supply 5 regulated J4 4 pin block Wiegand output to host or Data Clock output J5 5 pin block Wiegand peripheral input or Data C...

Page 19: ...ri ia al l p po or rt t w wi ir ri in ng g Terminal block J7 Pin 1 Rx Input Pin 2 Rx Input Pin 3 Tx Output Pin 4 Tx Output Pin 5 Ground Ground For a half duplex RS422 connection only Tx Tx and ground...

Page 20: ...contactless card reader as defined in its install manual For more information about this option please contact your SAGEM sales representative E Et th he er rn ne et t w wi ir ri in ng g Terminal blo...

Page 21: ...in 7 TxD Output Pin 8 Not connected Pin 9 Ground Ground W Wi ie eg ga an nd d o ou ut tp pu ut t w wi ir ri in ng g Terminal block J4 Pin 1 Data 0 Output Pin 2 Data 1 Output Pin 3 LEDin Input Pin 4 Gr...

Page 22: ...ity Industry Association s Wiegand standard March 1995 The supply available to the peripheral is 12 V at 250 mA max D Da at ta a C Cl lo oc ck k o ou ut tp pu ut t w wi ir ri in ng g Terminal block J4...

Page 23: ...np pu ut t w wi ir ri in ng g Terminal block J5 Pin 1 Data Input Pin 2 Clock Input Pin 3 Not connected Pin 4 Not connected Pin 5 Ground Ground The electrical interface is 5 V TTL compatible SK 0000011...

Page 24: ...switch Pin 6 Tamper switch Pin 7 Tamper switch Relay ratings 1 A at 30 VDC according to the safety extra low voltage requirements 42 4 VAC max 60 VDC max independently of the power supply Tamper switc...

Page 25: ...utput Open Wiegand mode Closed Dataclock mode SW3 6 Reserved MA 200 300 SW3 must be open SW4 must be closed SW5 must be open SW6 must be open SW3 6 Reserved MA 220 SW3 must be closed SW4 must be open...

Page 26: ...Open Closed Dataclock mode Closed Closed Not allowed 26 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...

Page 27: ...ae and fingerprint capture mode 4 authentication contactless card reading ID and fingerprint capture with a local base mode 5 modes 0 and 3 merged Mode 6 authentication keyboard ID and fingerprint cap...

Page 28: ...erprint detection in identification mode Place your finger for Identification Please If the identification is successful the terminal triggers the access or returns the corresponding ID to central sec...

Page 29: ...be selected and used 5 4 version evolution Old base selection style is no more available To select base 0 to 9 simply press the corresponding key 7 for base 7 To select base 10 to 15 press then the se...

Page 30: ...the corresponding ID to central security controller Welcome 707251 IDENT OK Once the person s identification is done the terminal automatically loops back selects base 0 and waits for a new finger Thi...

Page 31: ...DA AT TA AC CL LO OC CK K MorphoAccess 200 and 300 Authentication mode with local database cfg Maccess Admin mode 1 This mode requires a peripheral equipment which will send the ID of the person to a...

Page 32: ...tion of 92745 Place your finger If the authentication is successful the terminal triggers the access or returns the user ID to central security controller Welcome 92745 AUTHENT OK If the authenticatio...

Page 33: ...ta are stored on the card according to the format detailed in the Contactless card data structure MorphoAccess 220 only section contactless authentication without database mode cfg Maccess Admin mode...

Page 34: ...card should contain the user ID Please present Contactless Smart Card So that MorphoAccess triggers the access or returns the user ID to the central security controller user should just present his MI...

Page 35: ...to the terminal Please present Contactless Smart Card If card contains user templates user is invited to place his finger for biometric authentication Place your finger For authentication Please If ca...

Page 36: ...tion user should present his MIFARE card to the terminal Please present Contactless Smart Card Then user is invited to enter his PIN code Please enter PIN If the authentication is successful the termi...

Page 37: ...BIOPIN To trigger authentication user should present his MIFARE card to the terminal Please present Contactless Smart Card Then user is invited to enter his PIN code Please enter PIN If authenticatio...

Page 38: ...thentication is successful the terminal triggers the access or returns the user ID to the central security controller Welcome John Smith AUTHENT OK 38 SAGEM D fense S curit document Reproduction and d...

Page 39: ...modes are the same that the one described before refer to previous paragraphs and apart from card mode data data requested are the same too Card mode value Authentication method Data requested in add...

Page 40: ...D C CA AR RD D ID on a MIFARE card local templates MorphoAccessTM 220 Contactless authentication with database cfg Maccess Admin mode 4 Contactless authentication with database id format cfg Maccess...

Page 41: ...ID stored on the card Please present Contactless Smart Card If the ID exists in the selected database the MorphoAccess performs an authentication using the biometric templates associated to this ID On...

Page 42: ...a given offset on the card and is supposed to be binary This mode is useful for using the card serial number as an identifier Contactless authentication with database cfg Maccess Admin mode 4 Contact...

Page 43: ...n fails a second attempt is possible without representing the card ID offset from first read bloc cfg Maccess Contactless ID offset 0 15 ID offset in the first read block B parameter ID size in bytes...

Page 44: ...ormat ID is stored under 182469953390769 in the database ID format in the database is ASCII The record ID must be 182469953390769 0x31 0x38 0x32 0x34 0x36 0x39 0x39 0x35 0x33 0x33 0x39 0x30 0x37 0x36...

Page 45: ...sing a set of biometric and databasing management function interface access commands Proxy Mode For more information please contact SAGEM or refer to document MorphoAccess Host System Interface Specif...

Page 46: ...is finger operation identical to identification mode run a contactless authentication if user places his MIFARE card operation identical to contactless authentication without database mode If there is...

Page 47: ...ser is invited to place his finger for biometric authentication The default screen invites the user to enter his numerical identifier Enter your ID to erase Note ID length is limited to 24 numerical c...

Page 48: ...ccess 200 only The MorphoAccess shall be configured in one of either of these modes see this chapter 2 Access to the set up functions of the system request Administrator mode Note The MEMS handles the...

Page 49: ...ication receives the commands from MEMS it will switch to base management mode The operations sent by MEMS are automatically registered in the database of the MorphoAccess terminal Managing a base loc...

Page 50: ...KEYS MORE B Bi io om me et tr ri ic c m ma an na ag ge em me en nt t i in n s st ta an nd d a al lo on ne e m mo od de e MorphoAccess 200 only In stand alone mode the MorphoAccess manages its own loc...

Page 51: ...L L menu You have to enter the ID of the person and validate it The primary and secondary fingers are requested and their corresponding biometric templates are processed If the process is successful t...

Page 52: ...f fa ac ct to or ry y s se et tt ti in ng gs s To reset configuration to factory settings select the R R R S S S T T T C C C F F F G G G menu option A screen appears to confirm your command Configura...

Page 53: ...M M M O O O R R R E E E key select the R R R E E E B B B O O O O O O T T T key cfg Maccess parameters are updated immediately and reboot action is unnecessary SK 0000011145 05 SAGEM D fense S curit do...

Page 54: ...to delete the last digit entered The password can be changed in the configuration file cfg system see section MorphoAccess System Administrator Pin page 59 Note It is advised to change this password...

Page 55: ...ETTING EXIT MORE The S S S E E E T T T T T T I II N N N G G G menu allows you to set the LCD contrast and the time and date SK 0000011145 05 SAGEM D fense S curit document Reproduction and disclosure...

Page 56: ...ture file section parameter value They can be edited directly using the keyboard FILE cfg net SECTION ip Address 134 1 32 214 PREV NEXT EXIT EDIT The How to edit parameters network parameters section...

Page 57: ...menu displays cfg net Section selection Press the E E E D D D I II T T T key The Section menu displays ip Parameter selection Press the N N N E E E X X X T T T key until address is displayed then pre...

Page 58: ...cursor The E E E X X X I II T T T key aborts editing and restores the previous address value The IP subnet mask and IP default gateway are set up in the same way Contact your network Administrator fo...

Page 59: ...to system application Default value is 12345 FILE cfg system SECTION System Pwd 12345 PREV NEXT EXIT EDIT M Mo or rp ph ho oA Ac cc ce es ss s A Ad dm mi in ni is st tr ra at to or r P Pi in n Admini...

Page 60: ...rminal and MorphoAccess Enrollment Management System MEMS To configure the MorphoAccess terminal to manage the local database this default value must be changed to 0 COM1 or COM2 mean serial link admi...

Page 61: ...of population Since the encoding time is a little bit longer when the juvenile option is turned on we offer the possibility to the user set up the terminal either in Juvenile mode or in standard mode...

Page 62: ...thod If the user is not identified a second step follows immediately using a smarter coding method gabor coding This coding allows recognizing users with dry fingers or fingers with a bad placement on...

Page 63: ...Coding duration FILE cfg Maccess SECTION bio advanced timeout 2 PREV NEXT EXIT EDIT The cfg Maccess Bio advanced timeout parameter allows setting in seconds the period while the gabor coding will be...

Page 64: ...n convenience is the most important factor the FNMR must be low and conversely if security is more important then the FMR has to be minimized Different tuning are proposed in the MorphoAccess terminal...

Page 65: ...gnitions 1 Very few persons rejected FAR 1 2 FAR 0 3 3 Recommended value default value FAR 0 1 4 FAR 0 03 5 Intermediate threshold FAR 0 01 6 FAR 0 001 7 FAR 0 0001 8 FAR 0 00001 9 Very high threshold...

Page 66: ...System Interface Specifications The default language of the MorphoAccess is defined in the cfg Maccess Language default The allowed values are Default language cfg Maccess Language default 0 English...

Page 67: ...r This information should be present in the additional fields of its record Welcome Field 1 Field 2 IDENT OK The allowed values are Identification information local database cfg Maccess G U I Welcome...

Page 68: ...nger For identification Please 01 15 24 Time is displayed in the 24 hours format Display hour cfg Maccess G U I display hour 0 Clock is not displayed 1 Clock is displayed and refreshes every minute I...

Page 69: ...ation messages Graphic mode activation cfg Maccess BMP mode enabled 0 Display uses graphic and text default and historical mode 1 Display uses bitmaps Bitmaps are contained in files picto0 bin picto1...

Page 70: ...by blocks as follows Block 0 Block 1 Block 2 Block 3 Secteur 0 Block 1 Block 2 Block 3 Sector 1 Block 4 Block 5 Block 6 Sector 15 Block 46 Block 47 Bloc 48 Blocks are numbered in an absolute way 1 for...

Page 71: ...0 zero by the ILV command Default_Init and by the RST CFG action of the Administrator mode First block number to read cfg Maccess contactless B 4 default to 13 Number of blocks to read form B cfg Macc...

Page 72: ...N N F F F I II G G G menu in file cfg Maccess in section Admin The allowed values are Log activation cfg Maccess Admin Log file 0 MorphoAccessTM is not logging its activities 1 MorphoAccessTM is logg...

Page 73: ...is defined by slots of 15 minutes over a week For more information see MorphoAccess Host System Interface Specifications Time mask activation cfg Maccess Admin Time mask 0 Time mask feature is disable...

Page 74: ...sed to communicate with this agent please contact your SAGEM sales representative SDL activation cfg sdl Download Active 0 Inactive 1 SDL commands are allowed default Password to present in order to c...

Page 75: ...ataclock ports are compatible with ISO track 2 data formats I O Dataclock are ISO2 compliant In Wiegand mode ID is sent in binary format In Dataclock mode ID is sent in BCD format W Wi ie eg ga an nd...

Page 76: ...tification error for unknown person in base mode 4 Not ident ID 0 65535 default Identification error for not identified person TimeOut ID 0 65535 default Identification error for authentication time o...

Page 77: ...e Dataclock level key in section cfg Maccess Wiegand Dataclock Dataclock level cfg Maccess Wiegand dataclock Dataclock level 0 Data and strobe are not inverted default 1 Strobe is inverted 2 Data is i...

Page 78: ...y goes to dataclock out Wiegand IN Wiegand OUT led out DataClock IN Wiegand OUT inactive 1 Force Led out The led out signal only behaves as a led out signal 78 SAGEM D fense S curit document Reproduct...

Page 79: ...d in port is used as a dual led in port D1 is connected to Led in green and D0 to Led in red This feature improves integration in an access control system ACS Result of biometric matching is validated...

Page 80: ...They can be fixed to 0 or 1 or be used as parity odd or even bits calculated over bits of the frame Data In the Wiegand protocol three data are handled the Site code also called Facility code or Comp...

Page 81: ...No stop bit Site n m Insert m bits of site value at offset n ID n m Insert m bits of ID value at offset n Custom 0 0 Reserved for SAGEM custom protocols Note The number of bits of the Wiegand ID is l...

Page 82: ...be made using port 11020 Please refer to MorphoAccess Remote Messages Specifications for more information about this functionality ID sending on UDP cfg Maccess Ethernet Send 0 Not activated 1 L ID is...

Page 83: ...ss COM1 Send 0 Nothing is sent default 1 L ID is sent on COM1 ID transmission on port COM1 is disabled when ILV is activated on the same channel i e cfg Maccess Admin Host Com set to 1 COM1 parameters...

Page 84: ...Maccess Admin Host Com set to 2 COM2 parameters are defined by cfg ser1 Identifier format COM2 ID format COM2 cfg Maccess COM2 Format 0 L ID is sent in ASCII 1 L ID is sent in Hexa 2 L ID is sent in B...

Page 85: ...Baudrate bps cfg ser0 parameters baudrate 1200 bps 2400 bps 4800 bps 9600 bps default 19200 bps 28800 bps 38400 bps 57600 bps 115200 bps Data bits cfg ser0 parameters databits 5 5 databits 6 6 databit...

Page 86: ...XON XOFF U Us si in ng g a a D De ei is st te er r c co on nt ta ac ct tl le es ss s r re ea ad de er r o on n C CO OM M1 1 To connect a Deister reader on COM1 the serial link parameters must have th...

Page 87: ...tivated Relay parameters cfg Maccess Relay Active 0 default value Relay not active 1 reserved 2 Relay active Time in 100 ms 10 200 30 by default Relay aperture time in 100 ms SK 0000011145 05 SAGEM D...

Page 88: ...uch as temporary absences two additional functions corresponding to function keys 2 and 3 can be displayed After selection the MorphoAccess switches in biometric mode identification or authentication...

Page 89: ...section cfg Maccess time attendance The allowed values are Configuration time attendance cfg Maccess time attendance mode 0 Time attendance is disabled 1 Time attendance is enabled with two functions...

Page 90: ...re information about log configuration and retrieving refer to the MorphoAccess Host System Interface Specifications 90 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 00000111...

Page 91: ...technical support personnel Kernel is the name of the module being displayed Rev is the revision of the module P N is the part number for the module X is the checksum for the module The next line show...

Page 92: ...l number MicroBoot revision is the revision number of your SAGEM MorphoAccess s MicroBoot This revision number may be needed when requesting technical support ETH is the physical Ethernet address also...

Page 93: ...ows you to adjust the contrast of the LCD display T A The M M M O O O R R R E E E key increases the contrast the L L L E E E S S S S S S key decreases the contrast CONTRAST SETTINGS LESS MORE EXIT CON...

Page 94: ...T D D D A A A T T T E E E key allows you to set the current date Enter the date in the following format DDMMYY The V V V A A A L L L I II D D D key records your setting The C C C A A A N N N C C C E...

Page 95: ...d for that an administrator card containing the new keys to initialize Please check the Enrollment Station documentation to know how to create an administrator card While you are in the administrator...

Page 96: ...lease Present Admin Card Current Keys INVALID LOAD DFLT KEYS Pressing the L L L O O O A A A D D D D D D F F F L L L T T T K K K E E E Y Y Y S S S hotkey will allow you to re update the 32 keys with th...

Page 97: ...reader parameters describes the data location first block read M Mo or rp ph ho oA Ac cc ce es ss s T Ta ag gs s ID Tag Data type Size Tag Hex ID 24 0x32 This tag contains a unique card identifier Thi...

Page 98: ...ed finger according to the PKCOMP170 format PIN Tag Data type Size Tag Hexa PIN 15 0x33 This tag contains the user PIN code ASCII and numerical BIOPIN Tag Data type Size Tag Hexa BIOPIN 15 0x34 This t...

Page 99: ...will store previous and new keys This card is encoded with old keys and contains new keys S SA AG GE EM M k ke ey ys s Mifare 1K card Data Size Tag Hexa SAGEM keys 192 0x03 The keys are 6 bytes long...

Page 100: ...rrent key Key 1 will correspond to key A and will be copied in sector 0 Key 2 will correspond to key B and will be copied in sector 0 Key 3 will correspond to key A and will be copied in sector 1 Key...

Page 101: ...e Value field in bytes Value called V The parameters or data The commands will be encapsulated in a packet structure described on the next figure STX ID RC ILV CRC DLE ETX CRC compliance CRC16 V41 Fie...

Page 102: ...memory for data storage only on MA 300 P Pe er ri ip ph he er ra al ls s i in nt te er rf fa ac ce es s COM1 RS422 COM2 RS232C MA xx0 only Ethernet 10 Base T Wiegand or Dataclock ISO2 output Wiegand...

Page 103: ...s should be installed in controlled lighting conditions avoid direct exposure to sunlight UV Storage conditions Avoid exposure to UV S St to or ra ag ge e c co on nd di it ti io on ns s Temperature 20...

Page 104: ...ther liquids Do not expose your SAGEM MorphoAccess to extreme temperatures Use your SAGEM MorphoAccess with original accessories Attempts to integrate the MorphoAccess with unapproved accessories will...

Page 105: ...precision we recommend to synchronize regularly your terminal time with an external clock The terminal clock has a 40 10 6 ppm time deviation W Wa ar rn ni in ng g The manufacturer cannot be held res...

Page 106: ...tput Orange Green White 3 RX Receive Data Plus Input White Green White Orange Pink 4 No connection Blue Blue Orange 5 No connection White blue White blue Yellow 6 RX Receive Data Minus Input Green Ora...

Page 107: ...er bits are data bits The first bit transmitted is the first parity bit It is even parity calculated over the first 12 bits The last bit transmitted is the second parity bit It is odd parity bit calcu...

Page 108: ...2 odd parity calculated over the last 12 bits 34 bit Length 34 Start 0 0 reset to 0 Site 1 16 2 byte comparison number inserted in first ID 17 16 2 byte sequence number inserted in second Custom 0 0 S...

Page 109: ...l 8 0 0 0 1 0 8 9 1 0 0 1 1 9 10 Ahex 0 1 0 1 1 unused character 11 Bhex 1 1 0 1 0 start sentinel start character 12 Chex 0 0 1 1 1 unused character 13 Dhex 1 0 1 1 0 field separator 14 Ehex 0 1 1 1 0...

Page 110: ...bits in the telegram including start and stop sentinel The fifth bit is the odd parity of the 4 LRC bits it is not calculated over all the parity bits Input data should be preceded and followed by a c...

Page 111: ...c ck k l le ev ve el ls s In normal operation mode default input and output signals are defined as Other modes are only for output SK 0000011145 05 SAGEM D fense S curit document Reproduction and disc...

Page 112: ...cfg lcd0 contrast value 0 cfg serx mode connection EXT cfg serx mode mode 450 db seq flash start 0 cfg bio video channel 0 cfg bio video rotation 0 cfg lic licences cfg bio base n timestamp 0 cfg Macc...

Page 113: ...ontact of your finger on the terminal you must leave your finger on the sensor until sensor light is turned off Fingerprint Placement Fingerprint Orientation Area containing most of the information Fi...

Page 114: ...nts on card N No o 4 Contactless authentication with ID on card Y Ye es s 5 Fusion mode 0 and 3 Y Ye es s 6 Authentication with ID entered through the keyboard Y Ye es s Mode 3 and 5 allows defining t...

Page 115: ...control Wiegand Dataclock Ethernet and Serial Finger Positioning Highlight finger positioning principles MorphoAccess Screen Customization Explain how to create personalized screen Database Manager Us...

Page 116: ...D DR RI IL LL LI IN NG G T TE EM MP PL LA AT TE E 116 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...

Page 117: ...SK 0000011145 05 SAGEM D fense S curit document Reproduction and disclosure forbidden 117...

Page 118: ...SAGEM D fense S curit Si ge social Le Ponant de Paris 27 rue Leblanc 75512 PARIS CEDEX 15 FRANCE Soci t anonyme directoire et conseil de surveillance au capital de 36 405 229 562 082 909 RCS PARIS...

Reviews: