E
E
x
x
a
a
m
m
p
p
l
l
e
e
s
s
The corresponding configuration keys are in file /cfg/Wiegand in either
section IN or OUT:
26-bit: default format
/Length: 26
/Start: 2.12
//even parity calculated over the first 12 bits
/Site: 1.8
//1-byte facility code inserted in first
/ID: 9.16
//2-byte ID inserted in second
/Custom: 0.0
/Stop: 3.12
//odd parity calculated over the last 12 bits
34-bit
/Length: 34
/Start: 0.0 //reset to 0
/Site: 1.16 //2-byte comparison number inserted in first
/ID: 17.16 //2-byte sequence number inserted in second
/Custom: 0.0
/Stop: 1.0
//set to 1
37-bit: HID format
/Length: 37
/Start: 2.18
//even parity calculated over the first 18 bits
/Site: 0.0
/ID: 1.35
//35-bit ID (max value is 4294967295)
/Custom: 0.0
/Stop: 3.18
//odd parity calculated over the last 18 bits
108
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000011145-05
Summary of Contents for MORPHOACCESS 200
Page 1: ...SAGEM D fense S curit MORPHOACCESS TM Installation Guide MorphoAccessTM 200 220 300 July 2006...
Page 2: ...2 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...
Page 8: ...8 SAGEM D fense S curit document Reproduction and disclosure forbidden SK 0000011145 05...
Page 117: ...SK 0000011145 05 SAGEM D fense S curit document Reproduction and disclosure forbidden 117...