Saga SAGA1-L Series Installation & Operation Manual Download Page 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

INSTALLATION &   

OPERATION 

MANUAL 

Summary of Contents for SAGA1-L Series

Page 1: ...INSTALLATION OPERATION MANUAL...

Page 2: ...ccessories Chapter 4 Operation 4 1 Transmitter Configuration 4 2 General Operation 4 3 Special Functions Operation 4 4 The Use of Copier 4 5 Change of Frequency 4 6 ID Code Remote Setting 4 7 Receiver...

Page 3: ...is product must be returned to a service facility designated by GAIN Buyer will pay shipping charges to GAIN while GAIN will pay return shipping charges 1 3 Excluded Items This warranty does not inclu...

Page 4: ...witch and other required safety devices 8 Don t use this device during electrical storm or where there are conditions of high electrical interference 9 Ensure that the Transmitter batteries are in goo...

Page 5: ...EMS mushroom when malfunctions or abnormal conditions occur 7 The operator must be familiar with the following Emergency Procedures before operating 2 3 Emergency Procedures In case of emergency plea...

Page 6: ...ies 5 Chapter 3 Standard Accessories A standard and full set of SAGA1 L10 L12 is consist of Transmitter strap included 1 unit Receiver 1 unit Transmitter strap included 1 unit Receiver 1 unit SAGA1 L1...

Page 7: ...AGA1 L10 SAGA1 L12 Figure 4 1 Transmitter Configuration 1 Antenna 6 F1 Pushbutton 2 Emergency Stop 7 Start Pushbutton 3 LED Indicator 8 Battery Cover 4 Motion Pushbutton 9 Rotary Key Switch 5 Aux Push...

Page 8: ...ial Functions Operation 4 3 1 Power On operations Power on means that the Main Relay on the receiver will switch on as soon as the transmitter sends a signal and then the receiver will be on standby f...

Page 9: ...ress inching pushbutton 4 4 The Use of Copier 1 Insert the six pins female plug of copier into the male socket inside the TX or RX of SAGA1 L10 L12 2 For copying and saving the data from TX or RX put...

Page 10: ...the system 3 Use a needle nose pliers to straighten both pins of the new crystal unit 4 Insert the new crystal unit vertically into the PC board 5 Press the new crystal down into the socket Note To r...

Page 11: ...d hold it c Press DOWN pushbutton 4 times and release EMS UP pushbuttons when the red light on the transmitter is flashing d Start the system as usual ATTENTION In case ID Code remote setting fails re...

Page 12: ...wer select the proper voltage and plug in the connector 4 8 Transmitter Battery Adoption Two AA size alkaline batteries are required for the transmitter The LED will flash green when the battery power...

Page 13: ...e ON OFF Two relative pushbuttons are set to respectively control the same relay If a pushbutton set as on is pressed and released thus the relay remains conductive At this time the other pushbutton c...

Page 14: ...e certain period of time to operate a short but precise movement Press and hold inching pushbutton and then press motion pushbutton to perform the inching motion Acceleration When the motion is at the...

Page 15: ...selected time Continuous Never off Transmitter will keep sending signal unless turned off manually 3 Auto Off 1 Enable 2 Disable Enable When Transmit Mode is for continuous it will send an EMS signal...

Page 16: ...th the function of Normal and Control by EMS are going to de energize and it is essential to recommence the procedures of Power On again to continue operating 2 Passive Act Timing 0 1 4 0 sec The dura...

Page 17: ...Their corresponding relation is shown as below Means relay is on Means relay is off UP Down 1 Normal Normal 1st Step 2nd Step 1st Step 2nd Step 2 Toggle Toggle 1st Step 1st Step 3 On Off 1st Step 1st...

Page 18: ...sed and held when pushing or turning Start pushbutton or key to reach third speed 8 Digital Acce Digital Acce 1st Step 2nd Step 1st Step 2nd Step 3rd Step 4th Step 3rd Step 4th Step Note The second st...

Page 19: ...ion and Operation Guide 1 Software Installation 1 1 Open CD Rom of your computer and insert SAGA1 L10 L12 PC software CD the program will run automatically Click Install to proceed installing Cancel t...

Page 20: ...CD Rom The program will add a shortcut on your desktop 2 Software Operation and Function Setting 2 1 To activate the program either double click on the desktop shortcut for SAGA1 L10 L12 software or f...

Page 21: ...L Series 20 2 2 Default and second page of the program Default Page Function Setting Second Page Customer Info Open File Save File Print Switch to 2nd Page COM Port Setting Click here to exit the pro...

Page 22: ...hanging the function setting refer to Appendix I II either to save the setting data to computer hard disk or write it to another transmitter or receiver To save the data click Save File after destinat...

Page 23: ...Second page Customer Info of the program is to store the customers basic information and their setting data convenient for file sorting and further service such as to make copy of their lost or malfun...

Page 24: ...t the new COM via MAIN relay for double indemnity but go alone when this relay function is meant to bypass EMS Extra fuse is necessary when adding new COM For SAGA1 L10 one more COM line to use on Dow...

Page 25: ...Frequency Range 433 05 434 79 MHz ID Code 32 Bits Channel Space 250 KHz Hamming Distance 4 Housing Material Reinforced Plastic and Glass Fiber Protection Class IP65 Operating Temp 40 80 Maximum Operat...