158
Formwork restraint
Unless stated otherwise, all dimensions are given in mm.
14.2.3 Struts for formwork heights up to 3.90 m
The MANTO Alignment Struts are used with formwork heights of up to 3.90 m. The strut
is attached to a rib of the MANTO panel which can be either in a horizontal or vertical
orientation.
Props must be placed as near as possible to the vertical panel joint or the centre pro-
file.
For information on the Safe Working Loads, please refer to pages 35 - 38 and
α
X
Strut Base
Strut Base joint
MANTO Strut Head
(code:600035)
attached to the panel in the hori-
zontal orientation.
MANTO Strut Head
attached to the panel
in the vertical orien-
tation.
MANTO Alignment
Strut (code:565103)
Summary of Contents for Huennebeck MANTO G3
Page 1: ...MANTO Large frame panel formwork User guide...
Page 9: ...9 Unless stated otherwise all dimensions are given in mm MANTO...
Page 61: ...61 Unless stated otherwise all dimensions are given in mm MANTO MANTO G3 M MANTO G3 M...