background image

Figure 1. Battery SAFT LS26500

For Battery life estimation, please refer to this link.

Figure 2. Product package of WSSFCEX-GHC-01

With the default configuration, the device can be connected quickly to the Sigfox Network by the following steps.

Device ID

Get Devive ID on the device nameplate 

Device PAC

Get Devive PAC on the device nameplate 

1.2 What's in the package?

The package includes the following items:

01 x Main device

01 x Magnet key

01 x Antenna Type N connector

1.3 Quick Test

Step 1: Prepare the values of communication settings:

Note: All Sigfox sensors are pre-configured with the correct RC before delivery. The settings of Device ID,
Device PAC, and RC could also be read from the device memory map. Please reference section 

3.2 Sensor

configuration

 for details.

Summary of Contents for WSSFCEX-GHC

Page 1: ...gfox Product Type 1 part Mounting Type Wall mount Powered by 1 x C battery LiSOCl2 recommend SAFT LS26500 Information Changes in this version v s the previous version Item Changes Changed by Changed D...

Page 2: ...the device Case 5 During the commissioning testing or calibration sensor the user can force the device to send the uplink message to get the data immediately This message is called FORCE_DATA The pay...

Page 3: ...late Device PAC Get Devive PAC on the device nameplate 1 2 What s in the package The package includes the following items 01 x Main device 01 x Magnet key 01 x Antenna Type N connector 1 3 Quick Test...

Page 4: ...batteries into the device in Safe Zone Step 2 Add the device to Sigfox Backend Step 3 Install the batteries to the device After installing the battery in 60 seconds the first data packet will be sent...

Page 5: ...iptions Consumable parts replacement Yes The battery is the only part need to check the lifetime to replace Check the battery status on the back end system Cleaning device No Please refer to this link...

Page 6: ...e estimation please refer to this link measure_period Default 300s This is the time period for the wireless transmitter to wake up and take the measurement from the transducer The default value is 360...

Page 7: ..._VERSION string Read 6 6 3 2 HW_VERSION string Read 8 8 3 2 DEVICE_ID hex Read Product ID 10 A 3 4 DEVICE_PAC hex Read Product PAC 14 E 3 1 SENSOR_TYPE 1 255 uint16 Read Sensor or Input Type Read Writ...

Page 8: ...se time in second 307 133 3 16 2 C_H_FACTOR 4 4 float Read Write For methane C h 4 4 vol for propane C h 1 7 vol Please refer to this link Please refer to the detailed specifications inthis link For w...