MorphoAccess® SIGMA Series - Administrator Guide
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
401
July 17
Wiegand Parameters Settings
MorphoAccess® SIGMA Family terminals can communicate with distant systems, using Wiegand
interface. The protocol used for communicating on Wiegand channel is called Wiegand protocol.
It is required to configure Wiegand input and output string format that is understood by
terminal and distant system.
Several Wiegand formats are preloaded on MorphoAccess® SIGMA Family terminals and are
designated as a Standard type in the table below. They contain an ID of 32 bits or less. All
MorphoAccess® SIGMA Family terminals support these formats. Using Webserver, an
administrator can configure the desired Wiegand format for both input and output. “Standard
26-bits” is the default format. Besides Webserver, these configurations are possible via distant
commands also
.
Format
Type
Site Code Range
Template ID
Number Range
Extended ID
Number Range
Standard 26-bit (default) Standard 0 - 255
1 - 65535
N/A
Apollo 44-bit
Standard 0 - 16383
1 - 65535
N/A
Northern 34-bit
Standard 0 - 65535
1 - 65535
N/A
Northern
34-bit
[no
parity]
Standard 0 - 65535
1 - 65535
N/A
HID Corporate [35-bit]
Standard 0 - 4095
1 - 1048575
N/A
Ademco 34-bit (without
RCM code)
Standard 0 - 4095
1 - 1048575
N/A
HID 37-bit
Standard 0 - 2047
1 - 16777215
N/A
Auto Detect
Custom
As per the user field
(site-code
length)
defined in the custom
slot.
As per the Id
length defined in
the custom slot.
N/A
Table 3 :
Wiegand Format and Associated Values
Refer to “Authentication with local database: ID input from Wiegand or Clock & Data” to learn
more about authentication process when initiated through Wiegand or Clock & Data.