Section 3 :Installation Procedure
48
This document and the information therein are the property of Morpho.
They must not be copied or communicated to a third party without the prior written authorization of Morpho
2015_2000009096 V4
May 2017
6
Digital Output 2
Out
Reserved for Integrator Tamper Switch
Single Door Access Control (SDAC) implementation
Figure 26: SDAC wiring
If door contact is not used, GPI1 and GPO1 shall be connected together
Ethernet connection
Ethernet interface can be used to power the MorphoAccess Sigma Wave terminal
through POE (Power Over Ethernet - IEEE802.3af) mode. According to the POE standard
two modes are available: power on data pins and power on dedicated pins.
Use either one of these modes depending on POE implementation on your local
Ethernet network.
Ethernet cable shall be shielded
Default Ethernet configuration
By default, MorphoAccess Sigma Wave terminal is configured in Static mode.
IP address Mode
Parameter
Factory value
Static
Terminal IP address
192.168.1.10
Gateway IP address
192.168.1.254
Sub network mask
255.255.254.0
Host name
MAsigma
External
Power supply
1
6
1
6
1
6
1
6
A
B
C
D
Door
contact
GPI1
Door
strike
GPO0
Push button /
Motion sensor
GPI0
GPO1
RLY1
RLY2