LRF 7047- Integrator Manual
914929_TML_LRF7047_en_Version B
Public: 04.2019
Confidential & Proprietary
Safran Vectronix AG – All rights reserved
Page: 36/72
5.6 Serial Interface
5.6.1 RS232
The RS232 interface uses system connector pin#19 (RS232-TX) and pin#21 (RS232-RX) with the
following parameters:
Parameter
Value
Baud rate
57600 Bd
Data bits
8
Start bit(s)
1
Parity
Even
Stop bit(s)
1
Signaling levels
RS232 Levels
Please see chapter
5.2 Pin descriptions
for RS232/422 Interface selection with pin#18.
5.6.2 RS422
The RS422 interface uses system connector pin#17 (RS422-TX P), pin#19 (RS422-TX N), pin#21
(RS422-RX P) and pin#23 (RS422-RX N) with the following parameters:
Parameter
Value
Baud rate
57600 Bd
Data bits
8
Start bit(s)
1
Parity
Even
Stop bit(s)
1
Signaling levels
RS422 Levels
Please see chapter
5.2 Pin descriptions
for RS232/422 Interface selection with pin#18.
5.7 Pointer Interface: Interlock 1 to 4
To enable the non-eyesafe pointer, connect Interlock 1, 2, 3 and 4 together. If the Interlock pins are not
connected then there is no pointer emission possible. When the pins are connected, the corresponding
SW command (see chapter 6.5.4 and 6.5.5) can be sent to activate the pointer.
5.8 Ground Concept
The LRF System has to be connected to the host system ground via the three screws and the area
around the three screws. The LRF bench is conductive.