COMMAND RANGING & TELEMETRY UNIT CORTEX
Is.Rev.
Date:
© Safran Data Systems
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 1
2.3.2.
I/O Connectors description
2.3.2.1.
External interconnection panel
The connectors are described based on the groups of functions highlighted by lines and a general label on the interconnection panels.
For any signal, all characteristics and labels are identical whatever chassis is supplied.
C
ONNECTOR
T
YPE
C
ONNECTOR
P
ANEL
L
ABEL
C
ABLE
S
LEEVE
L
ABEL
MSP
MODULE
CONNECTOR
LABEL
SIGNAL
E
LECTRICAL CHARACTERISTICS
UPLINK
BNC Female
NOMINAL IF
1
UL
NOM
IF1
IF out
NOM 1
IFM-1 Nominal IF output port
50-90 MHz (-3 dB bandwidth)
0 to - 80 dBm, 50
BNC Female
ALTERNATE IF
1
UL
ALT
IF1
IF out
ALT 1
IFM-1 Alternate IF output port
DC-90 MHz (-3 dB bandwidth)
- 20 dBm, 50
BNC Female
NOMINAL IF
2
UL
NOM
IF2
IF out
NOM 2
IFM-2 Nominal IF output port
50-90 MHz (-3 dB bandwidth)
0 to - 80 dBm, 50
BNC Female
ALTERNATE IF
2
UL
ALT
IF2
IF out
ALT 2
IFM-2 Alternate IF output port
DC-90 MHz (-3 dB bandwidth)
- 20 dBm, 50
BNC Female
VIDEO IN
1
UL
V
IDEO
IN1
Note 1
Auxiliary video input to IFM-1
(analog signal)
100 Hz - 2 MHz
2 Vpp - 50
BNC Female
VIDEO IN
2
UL
V
IDEO
IN2
Note 1
Auxiliary video input to IFM-2
(analog signal)
100 Hz - 2 MHz
2 Vpp - 50