SSI-302-W Wiegand interface board advanced settings 

 

 

 
Copyright© 2018 - Saflec Systems (Pty) Ltd. 

www.saflecsystems.co.za 

 

Advanced settings 

Setting index 

Setting 

Values 

Description 

Address 

0-9: Addresses 0-9 
A- F: Addresses 10-15 

Device address on RS-485 

Baudrate 

1200 

2400 

4800 

9600 

19200 

38400 

57600 

115200 

125000 

250000 

500000 

 

When used to connect to barcode 
readers or devices using the 
serial UART, this will set the 
speed at which it communicates. 

Polarity 

0: Normal 
1: Inverted 

For the RS-232 

Reserved 

 

 

 

UART mode 

As discussed in the settings this device can also use a UART system at RS-232 input levels. This means that 
it can translate input from devices like barcode scanners into OSDP or into the SACS system. 
 
 
 
 
 
 
 

Figure 4 

SSI-302-W wired to serial device 

 
The device will automatically switch into UART mode if it receives serial communications at the correct 
Baudrate on the Wiegand Data 0 pin. From that point on until reboot the board will ignore the other Wiegand 
inputs. 
 
When access is allowed or denied by the controller it will transmit the serial 

‘Beep’ signal on the Wiegand 

buzzer output pin. Allowed will be 1 beep, denied will be 4 beeps. 
 

Note: 

The serial Baudrate and Polarity must be correctly configured before the device will use the serial bus. 