Saflec Systems SDC-320 Quick Start Manual Download Page 1

 

Copyright© 2016 

– Saflec Systems (Pty) Ltd. 

http://www.saflecsystems.co.za 

 

 

SDC-320 

Wiegand door controller 

Revision 1.0 - (May 12, 2016) 

 
 

Quick Start Guide

 

Introduction 

The SDC-320 is a multiple door controller that can control up to 8 doors. It has two relay outputs 
and four inputs. 
The PC can connect to it using the built-in Ethernet connector. 
It has a reader RS-485 network that can also connect up to sixteen slave devices including remote 
I/O units. This network also supports OSDP secure channel. 
Two Wiegand compatible devices can also be attached directly onto the controller. 
 
The unit comes with a 12Vdc 5A power supply and a battery backup of 7Ah and is mounted in a 
lockable case. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1 

SDC-320 Controller board - labeled

 

 

Summary of Contents for SDC-320

Page 1: ...our inputs The PC can connect to it using the built in Ethernet connector It has a reader RS 485 network that can also connect up to sixteen slave devices including remote I O units This network also...

Page 2: ...SDC 320 Wiegand door controller 2 Copyright 2016 Saflec Systems Pty Ltd http www saflecsystems co za Figure 2 Possible position for an SDC 320 in a SACS access control system...

Page 3: ...wer the panel will be active If the screen is blank it will be in screen saving mode Tapping any button will awaken the screen and allow you to configure the device Figure 3 The configuration and diag...

Page 4: ...ations network Each controller on this network requires a unique address for communications and identification Duplicate addresses will cause communication problems The address of the controller can b...

Page 5: ...p might cause the power to be insufficient The devices do not have to be powered from the controller They can also be powered individually from a separate power supply should this be preferable howeve...

Page 6: ...ep 5 Connecting the digital inputs Before wiring the digital inputs make sure that the power is switched off on the controller board When looking at the controller board with the power connector on th...

Page 7: ...for the output relays Figure 10 Example wiring for an externally powered magnetic lock Normally closed Output mode 2 Internally powered outputs To set the output to internally powered mode place two j...

Page 8: ...gand devices communicate with the SDC 320 via five signalling lines These lines can be broken into two groups The data lines Data 0 Data 1 The control lines Red LED Green LED and Buzzer Note Make sure...

Page 9: ...nterface front page It shows basic diagnostics information on the main page but the links at the bottom will require a username and password for authentication The default username is root and passwor...

Page 10: ...t Voltage 12 to 36Vdc Maximum Input Current 7 3 mA Outputs Output type Relay internally powered or potential free contact Maximum voltage AC 250Vac Maximum voltage DC 220Vdc Internally powered Outputs...